DESCRIPTION:
These utilities are designed to convert PSTN trace binary files to text format. The
binary PSTN trace files are generated when the user sets the PSTN interface to trace
mode.
OPERATION:
Generating a Trace/audit Text File for CAS Protocols
To generate a readable text file out of the binary trace file when
using CAS protocols, take these 3 steps:
1.
Rename the PSTN trace binary file to CASTrace0.dat.
2.
Copy it to the same directory in which the translation utility, CAS_Trace.exe, is
located.
3.
Run CAS_Trace.exe (no arguments are required). The text file, CASTrace0.txt, is
created.
Generating a Trace/audit Text File for ISDN/SS7/ATM Protocols
To generate a readable text file out of the binary trace file when
using ISDN/SS7/ATM protocols, take these 2 steps:
1.
Copy the PSTN trace binary file to the same directory in which the translation
utility CONVERT_TRACE.BAT is located. The following files should reside in the
same directory: Dumpview.exe, Dumpview.cfg and ReadMe.txt.
Read carefully the ReadMe.txt in order to understand the usage of the translation
utility.
2.
Run the CONVERT_TRACE.BAT. The text file is created.
20.4

Enabling PSTN Trace via the Web

This section contains direction on starting and collecting the PSTN trace via the Web.
(Refer to the figure below for a view of the Trunk Traces). Also, note if the PSTN trace
is of a ISDN/SS7/ATM or CAS collection based on the physical device involved in the
trace. This information is needed to properly parse the captured data.
To start and collect the PSTN trace via the Web, take these 12
steps:
1.
Run the UDP2File utility.
2.
Determine the trace file name.
3.
Determine the UDP port.
4.
Mark the PSTN Trace check box.
5.
Click the Run button. The UDP2File utility starts to collect the trace messages.
6.
Activate the Web page by entering <Mediant 2000 IP address>/TrunkTraces and
choose the Trunk Traces tab (e.g.,http://10.8.8.101/TrunkTraces).
7.
Use the user and password, which is the same for the unit.
8.
In the Web page, set the trace level of each trunk.
User's Manual