AudioCodes Mediant 2000 User Manual page 281

Mgcp, megaco, tpncp voip mediant media gateways
Hide thumbs Also See for Mediant 2000:
Table of Contents

Advertisement

User's Manual
Error Message Text
"PSTN Validation Check failed.
TDMBusLocalReference is
configured to be trunk number
= %d and the trunk isn't
configured to be Recover
Mode.',ImageBoardParams.TD
MBusLocalReference"
PSTN Validation Check failed.
TDMBusClockSource is set to
Network but all trunks are set
to acCLOCK_MASTER_ON
(master clock). Can't use other
trunks as recover clock. Set
one trunk to be
acCLOCK_MASTER_OFF.'
"PSTN Validation Check failed.
When configuring the board to
recover the clock from
PSTNTDMBusLocalReference,
the trunk must be active
(protocol type should not be
set to NONE).'"
PSTN Validation Check failed -
V5 Configuration Error.'
PSTN Validation Check failed.
All trunks configured with
protocol type NONE.
Reconfigure the trunks and
reset the board.'
"'acPSTNVcVsTrkValidationCh
eck() - VC is not as Trunk Line
Type - VC: %d Trk:
%d.',VcId,TrkId"
PSTN Trunk Validation Check
failed because of on-the-fly
changes is not supported on
this HW.'
PSTN Trunk Validation Check
failed. Protocol type must be
different from
acPROTOCOL_TYPE_NONE.'
Version 5.0
Table 9-3: User Error Messages
Probable Cause
User set
TDMBusLocalReference" to
"
specific trunk, but configured
it to be clock recover
(acCLOCK_MASTER_OFF=
0), and the
"AutoClockEnable" is
disabled.
User set the
TDMBusClockSource to
network (recover the clock
from one of the trunks)
therefore also one of the
trunks should be set to clock
recover
(acCLOCK_MASTER_OFF=
0).
User set
TDMBusLocalReference" to
"
specific trunk, but configured
this trunk to be un-used
(NONE), and the
"AutoClockEnable" is
disabled.
There is some problem with
the V5 configurations.
User configured all trunks as
NONE. The PSTN interface
is disabled (unless you work
with AMS profile).
User configured a wrong
"SDHFbrGrp_LP_Mapping_T
ype" compared to the board's
line type
This functionality is not
working for this module
(Hardware).
User is trying to configure the
protocol type to NONE.
281
9. Diagnostics & Troubleshooting
Recommended Action
Set the Local Reference trunk
"PSTNClockMaster " to
"acCLOCK_MASTER_OFF" (=0)
, or set "AutoClockEnable" to ON
(1). Reset the board after
changing the configurations.
Set at least one trunk's
"PSTNClockMaster " to
"acCLOCK_MASTER_OFF" (=0)
and reset the board.
Set the Local Reference trunk
"PSTNClockMaster " as an active
trunk , or set "AutoClockEnable"
to ON (1). Reset the board after
changing the configurations.
Look at the previous Syslog
messages to see the specific V5
error.
Set at least one trunk with a valid
protocol type, and reset the
board.
Set the
"SDHFbrGrp_LP_Mapping_Type"
parameters up to the line type
("TU12_E1" (=1) - for E1,
"TU11_DS1" (=2) - for T1) and
reset the board.
Don't try to make changes at the
module (Hardware).
Please choose the correct
protocol.
June 2006

Advertisement

Table of Contents
loading

Table of Contents