Mediant 2000
relevant only in case the tone is not Amplitude Modulated.
High Freq [Hz] - Frequency in Hertz of the higher tone component for of a dual
frequency tone, or zero (0) for a single tone. This parameter is relevant only in
case the tone is not modulated.
Low Freq Level [-dBm] - Generation level 0 dBm to -31 dBm. This parameter is
relevant only in case the tone is not Amplitude Modulated.
High Freq Level [-dBm] - Generation level. 0 to -31 dBm. The value should be
zero (0) for a single tone. This parameter is relevant only in case the tone is not
Amplitude Modulated.
First Signal On Time [10 msec] - "Signal On" period (in 10 msec units) for the
first cadence ON-OFF cycle, for cadence tone. When a tone is configured to be
continuous, this parameter defines the tone On event detection time. When a
tone is configured to be burst tone, it defines the tone's duration.
First Signal Off Time [10 msec] - "Signal Off" period (in 10 msec units) for the
first cadence ON-OFF cycle, for cadence tone. In case of burst tone, this
parameter defines the off time required after burst tone ended until the tone
detection is reported. For a continuous tone, this parameter is ignored.
Second Signal On Time [10 msec] - "Signal On" period (in 10 msec units) for
the second cadence ON-OFF cycle. This may be omitted if there is no second
cadence.
Second Signal Off Time [10 msec] - "Signal Off" period (in 10 msec units) for
the second cadence ON-OFF cycle. This may be omitted if there is no second
cadence.
Third Signal On Time [10 msec] - "Signal On" period (in 10 msec units) for the
third cadence ON-OFF cycle. This may be omitted if there is no third cadence.
Third Signal Off Time [10 msec] - "Signal Off" period (in 10 msec units) for the
third cadence ON-OFF cycle. This may be omitted if there is no third cadence.
Fourth Signal On Time [10 msec] - "Signal On" period (in 10 msec units) for the
fourth cadence ON-OFF cycle. This may be omitted if there is no fourth cadence.
Fourth Signal Off Time [10 msec] - "Signal Off" period (in 10 msec units) for the
fourth cadence ON-OFF cycle. This may be omitted if there is no fourth cadence.
Carrier Freq [Hz] – the Carrier signal frequency in case the tone is Amplitude
Modulated.
Modulation Freq [Hz] – The Modulated signal frequency in case the tone is
Amplitude Modulated (valid range from 1 Hz to 128 Hz).
Signal Level [-dBm] – the tone level in case the tone is Amplitude Modulated.
AM Factor [steps of 0.02] – Amplitude modulation factor. Valid values: 1 to 50.
Recommended values: 10 to 25.
Default Duration [msec] - The default duration (in 1 msec units) of the
generated tone.