User's Manual
Error Message Text
relevant to this trunk. Channel
ID = %d',CID"
PSTN Trunk Validation Check
failed. Insufficient DSP
resource when configuring
CAS trunk.'
CheckThatAllProtocolsAreCom
patabile(): TR08 configuration
failed. Check the syslog for
more information.'
"ProtocolType not valid for
TrunkId : %d.
ProtocolType
changed to
acPROTOCOL_TYPE_NONE.'
,i"
CheckThatAllProtocolsAreCom
patabile(): Illegal mix of
ProtocolTypes for Trunks.'
"'Action Failed -
IUACheckfForDoubleInterfaceI
d - duplicate Int_id
=%d.',ImageBoardParams.Ext.
IUATrunkConfig[TrunkId].IuaInt
erfaceId"'
"Error: When configuring the
board to recover the clock from
PSTNTDMBusLocalReference,
the trunk must be active. Trunk
number =
%d.',BoardParams.TDMBusLo
calReference"
"CheckProtocolTypeValidation(
) - All trunks configured with
protocol type NONE,
reconfigure the trunks and
reset the board.'"
It is illegal to set all trunks with
protocol type NONE.'
'InitializeAllFramesForNonePro
tocols() - Invalid Line type
(should be E1 or T1)'
Version 5.0
Table 9-3: User Error Messages
Probable Cause
open channels on this trunk.
User configured the trunk as
CAS but the board has
insufficient DSP resources
for this action.
You have a problem with the
TR08 configurations.
You worked with V5 but used
a protocol type that was not
suitable to V5.
You work with V5 but used
protocol types that were not
suitable to V5.
Trunk Validation error -
interface ID value is
duplicated.
User set
TDMBusLocalReference" to
"
a specific trunk, but it
configure this trunk to be un-
used (NONE), and the
"AutoClockEnable" is
disabled.
You will receive this error
every 30 Sec until you
change the configurations.
All trunks were configured
with "PotocolType" "NONE"
(=0), or there is some critical
problem at the PSTN
interface.
All trunks were configured
with "PotocolType" "NONE"
(=0), or there is some critical
problem at the PSTN
interface.
All trunks were configured
with "PotocolType" "NONE"
(=0), or there is some critical
problem at the PSTN
283
9. Diagnostics & Troubleshooting
Recommended Action
Try to configure another trunk as
the CAS trunk, or contact
AudioCodes to upgrade your
Hardware.
Look at the previous Syslog
messages to see the specific
TR08 error
Configure the protocol type of this
trunk to one of V5 family.
Configure all trunk's protocol
types to one of V5 family.
Remove the duplicated interface
ID.
Set the Local Reference trunk
"PSTNClockMaster " as an active
trunk , or set "AutoClockEnable"
to ON (1). Reset the board after
changing the configurations.
Set at least one trunk's
"ProtocolType" with a valid
protocol type (not NONE).
Set at least one trunk's
"ProtocolType" with a valid
protocol type (not NONE)
Set at least one trunk's
"ProtocolType" with a valid
protocol type (not NONE)
June 2006