High Temperature Threshold

High Temperature Threshold

A message can be defined that will display when a user-set High Temperature
Threshold has been reached. The message repeats once every 30 minutes until the
condition is corrected. This value is a reference to the external ambient temperature in
the environment around the scanner.
High Temperature Degrees
Usage:
Helps ensure that the scanner is being used within its temperature speci-
fication. Also, since hotter environments tend to shorten the life of elec-
tronics components, a user may want to set the temperature threshold
closer to the nominal temperature of 25°.
Definition:
A user can set a temperature value that when exceeded will cause a high
temperature message to be displayed. If High Temperature Threshold
is set to zero, then the warning message will be disabled
Serial Cmd:
<K+degrees,message>
Default:
50° Celsius
Options:
0° to 50°, zero disables.
High Temperature Message
Definition:
The user can enter a message of up to 10-characters that will be dis-
played whenever High Temperature Threshold is exceeded.
Serial Cmd:
<K+degrees,message>
Default:
HI-TEMP
Options:
Any 1 to 10 character ASCII string except NUL, <, or >.
MS-820 Industrial Bar Code Scanner User's Manual
8-10
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-820 and is the answer not in the manual?

Questions and answers

Table of Contents