Power
'
General
Voltage range, nominal
Line frequency, nominal
Inrush current
Current rating
Max. Power consumption
Current rating of AC input coupler
Type of connector @ projector
Line Cords (3 conductors)
Plugs
(@ 200VAC)
+
Roadster S
12K
+
Roadster S
16K
+
Mirage S
14K
+
Roadster S
20K
(@ 200VAC)
+
Roadster S
12K
+
Roadster S
16K
+
Mirage S
14K
+
Roadster S
20K
+
Roadster S
12K
+
Roadster S
16K
+
Mirage S
14K
+
Roadster S
20K
+
Roadster S
12K
+
Roadster S
16K
+
Mirage S
14K
+
Roadster S
20K
+
Roadster S
12K
+
Roadster S
16K
+
Mirage S
14K
+
Roadster S
20K
+
Roadster S
12K
+
Roadster S
16K
+
Mirage S
14K
+
Roadster S
20K
(Roadster S+ 20K plug not shown)
SPECIFICATIONS
200 – 240 VAC ±10%
50 – 60 Hz
60 A max.
12 A
16 A
16 A
24 A
2400 W
3200 W
3200 W
4800 W
15 A
20 A
20 A
n/a
IEC320-C14
IEC320- C19
IEC320- C19
n/a — not detachable from projector
Heavy duty, 14 AWG
Heavy duty, 12 AWG
Heavy duty, 12 AWG
Heavy duty, 12 AWG
NEMA 6-15P, 15 A, 250 VAC
NEMA 6-20P, 20 A, 250 VAC
NEMA 6-20P, 20 A, 250 VAC
L6-30, 30 A, 250 VAC