Inner Basket Pulley - ALLIANCE HWF561*E1102 Service

Commercial front control washers
Table of Contents

Advertisement

Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
WASHERS
SCREW
NUT
CLAMP
RING
SEAL
Figure 38
110
OUTER TUB
FRONT PANEL
GROUND
WIRE
H121SE1A
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
WARNING

60. INNER BASKET PULLEY

a. Unlock control panel. Refer to Figure 17, Step
1.
b. Pull top of control panel away from control
cabinet far enough to allow lifting control panel
up and off rail support of the control cabinet.
Refer to Figure 17, Step 2.
c. Remove control panel away from control
cabinet as far as wires permit. Refer to
Figure 17, Step 3.
d. Remove two screws holding front of cabinet
top to top front edge of control cabinet front.
Refer to Figure 19.
e. If area or space permits, lift cabinet top to a
vertical position by hinging it on the rear
hinges.
NOTE: To avoid hinge damage, be sure to support
cabinet top with a small chain or something similar.
Refer to Figure 21.
f. Run belt off pulley while slowly turning pulley.
g. Remove belt from motor shaft.
h. Remove cap screw (left hand thread)
lockwasher and flat washer holding pulley to
inner basket shaft. Refer to Figure 39.
i. Remove pulley from shaft.
IMPORTANT: When installing pulley, always use a
new cap screw to prevent screw from loosening
during operation.
NOTE: When installing new cap screw, apply a
thread locking compound to screw threads and
torque new cap screw to 240 minimum to 260
maximum inch pounds (27.5 to 29.7 Nm).
j. After installing belt, adjust belt tension per
Paragraph 65.
W003
800168

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents