2 Installation

2.1

Supply and Voltage Connection

2.1.1

V100 Versatile Multiplexer

A.C. 85-250V, 50/60Hz. Fuse rating 2A anti-surge. The V100 has a fused, filtered IEC inlet which must be
connected to a line voltage within the range specified above. It may be operated only within the above
limits. EMC performance may be affected if operated below 100V A.C.
2.1.2

V100 Compact Multiplexer

D.C. 9-36V or 18-72V, must be specified to the factory. Fuse rating 3A anti-surge. The V100 has a fused,
diode-protected DC inlet, which must be connected to a line voltage within either of the ranges specified
above.
2.2

Environmental

The V100 must be operated under the following conditions:
Ambient Temperature 0-50 degC
Humidity 0-90% RH non-condensing
Pressure 86-106 Kpa
2.3

Mechanical Construction

2.3.1
V100 Versatile Multiplexer
The V100 is housed in a 1U tall 19" rack-mount enclosure with an externally mounted fan and guard. The
enclosure comprises four parts incorporating chassis, inner front panel, outer front panel and lid. The lid is
retained by 15off M3 black, anodised, posidrive screws.
The front panel has indicators for PORT1 and PORT2 status (flashing red or green), TEST (red/green) and
OPTION 0 (on RevD units), OPTION1 and OPTION2 data activity (red/green). The meaning of these
indicators is discussed in Section 4.1. It also presents the 10/100base-T Ethernet port.