Installation; Supply And Voltage Connection; Environmental; Mechanical Construction - Vocality V200 User Manual

Table of Contents

Advertisement

3

Installation

3.1

Supply and Voltage Connection

110-240V AC +/-10% 47-63Hz. Fuse rating 8A anti-surge. The V200 uses a modular,
filtered supply with an IEC inlet which must be connected to a line voltage within the
range specified above. It may be operated only within these limits.
3.2

Environmental

The V200 unit must be operated under the following conditions:
External Temperature 0-50degC ambient
Humidity 0-90%RH non-condensing
Pressure 86-106 kPa
WARNING: Do not obstruct the two cooling fan inlets on the outer front panel at
3.3

Mechanical Construction

The V200 is housed in a 3U tall 19" rackmount enclosure. The enclosure comprises four
parts incorporating chassis, inner front panel, outer front panel and lid. The outer front
panel houses two cooling fan inlets, which must not be obstructed at any time, and ten
light pipes leading to LED indicators inside. This panel may be safely removed during
operation without turning the unit off, for the purpose of inspecting/changing the fan
filters.
WARNING: Removing panels, other than the outer front panel, will void your
warranty. There are no other user-serviceable parts inside.
The enclosure comprises of 10 bays A through J. Bay A houses a CPU card and bay J
houses a power supply card. Bay I may house a power supply card, a CPU card, or any
available option card. Bays B through H may only house a CPU card or an option card.
any time or the unit may overheat
Vocality User Manual
User Manual for V200
Valid for V08_08.02 or V08_48.02
Page 16 of 114