9.6
Supervisor Cables
MUX 9-way Male
Connector
UNC 4/40 Screws
Shield
1
2
3
4
5
8
Notes:
•
Cable type: Belden 6 separate conductors, overall screen (or equivalent). Maximum
length 5 metres.
•
For automatic use in Teletype Mode, connections to pins 4 and 8 should be omitted and
a shorting link fitted between them at the MUX end.
MUX 9-way Male
Connector
UNC 4/40 Screws
Shield
2
3
5
Notes:
•
Cable type: Belden 3 separate conductors, overall screen (or equivalent). Maximum
length 5 metres.
V100 Versatile Multiplexer Technical Manual Version 2.2
RS232/V.24 STRAIGHT
9-way Multiplexer Supervisor DCE to Terminal DTE Cable
(Part Number VI68724A)
Terminal 9-way
Female Connector
UNC 4/40 Screws
Shield
1
2
3
4
5
8
RS232/V.24 STRAIGHT
9-way Multiplexer Supervisor DCE to Modem DCE Cable
(Part Number VI68724B)
Modem 9-way Male
Connector
UNC 4/40 Screws
Shield
2
3
5
Page 224 of 231
C H A P T E R
9
A P P E N D I X
Signal Name
SHIELD
DCD
RXD
TXD
DTR
GND
CTS
Signal Name
SHIELD
RXD
TXD
GND
D :
C A B L E S
Signal Type
(at mux end)
SHIELD
Output
Output
Input
Input
Ground
Output
Signal Type
(at mux end)
SHIELD
Output
Input
Ground