ValueJet 1304 Service manual
9.2.2
Errors with Message
This section describes the contents of errors with messages as well as the check items and recovery actions.
These messages are displayed when an abnormal condition occurs while the machine is running.
Upon an occurrence of an error with message, the machine stops its operation at the same time.
The error can be cancelled by removing the error causes. After that, the machine will restart its operation.
Table 9-3 Events and Check Items for Errors with Messages
No.
Message
1
Undefined
Media
Event/
Check item
symptom
Media
1. Is P_EDGE sensor
detection failed
assembly cable at
head connected
correctly?
2. Is P_REAR sensor
under media guide
R connected
correctly?
3. Check sensor
sensitivity from
"Sen 6:EdgeAD" of
self-diagnosis
function.
4. Is CR cable inserted
obliquely?
5. CR cable may be
broken.
6. CR board assembly
may be damaged.
Securely connect it to
CR board assembly
connector J211.
Securely connect it to
main board assembly
connector J130, J131.
•
Adjust with main
board assembly
volume (R361,
R365).
•
Replace P_EDGE
sensor assembly.
Reconnect following
connectors.
•
Main board
assembly: J110 -
J114
•
CR board: J201 -
J205
Replace CR cable.
Replace CR board
assembly.
9-5
Action
Reference
"4.10.1
Replacing CR
Board
Assembly"
p.4-91
"4.3.3
Replacing
Main Board
Assembly"
p.4-29
"7.11.1
P_EDGE
Sensor
Sensitivity
Adjustment"
p.7-45
"4.3.3
Replacing
Main Board
Assembly"
p.4-29
"4.10.1
Replacing CR
Board
Assembly"
p.4-91
"4.10.3
Replacing CR
Tape Wire"
p.4-97
"4.10.1
Replacing CR
Board
Assembly"
p.4-91
AP-74109 Rev 1.1