MUTOH ValueJet Service Manual page 340

Wide format
Table of Contents

Advertisement

Table 9-6 Error Messages During File Transmission (Continued)
No.
Message
11
Internal Error
Memory
Exhausted
12
Transfer failed
Block replay
timeout
13
Transfer failed
Block replay
error xx
14
Transfer failed
Final reply
timeout
15
Transfer failed
Final reply
error xx
AP-74109 Rev 1.1
Event/
Check item
symptom
No memory
Normally not occurred.
area is
SODIMM may be
available.
defective.
"Block reply
Check connection
timeout"
between control board
occurred
and main board.
during system
code transfer.
Invalid value is
received during
system code
transfer.
"Final reply
timeout"
occurred
during system
code transfer.
Invalid value is
received during
final system
code transfer.
ValueJet 1304 Service manual
Replace SODIMM.
Replace main
board.
Reconnect control
board and main
board.
Replace the cable
connecting control
board and main
board.
Replace control
board.
Replace main
board.
9-26
Action
Reference
"4.3.3
Replacing
Main Board
Assembly"
p.4-29
"4.3.4
Replacing
HEATER
CONT board
assembly"
p.4-30
"4.3.3
Replacing
Main Board
Assembly"
p.4-29

Hide quick links: