ValueJet 1304 Service manual
9.2.1
Operation Status
This section describes the message contents, check items, and recovery actions for normal operation.
These messages appear on LCD, and the machine stops its operation at the same time.
Table 9-2 Events and Check Items for Operation Status Messages
No.
Message
1
Cover Open
2
Lever Up
Event/
Check item
symptom
Front cover is
Is cover sensor
open.
assembly loose?
Media holding
1. Is cover sensor
lever is turned
assembly cable
backward.
connected securely?
2. Does pressure lever
move smoothly?
3. Is lever sensor
assembly fitted
correctly?
4. Is sensor of lever
sensor assembly
contaminated?
5.
Is lever sensor
cable connected
securely?
6. Check the cover
sensor from "Sen
4:Cover" of self-
diagnosis function.
7. Check the lever
sensor from "Sen
5:Lever" of self-
diagnosis function.
Tighten cover sensor
assembly screws.
Correctly connect cover
sensor assembly cables
to main board assembly
connector J117.
Lubricate pressure cam.
Adjust lever sensor
assembly position.
Clean sensor face using
a swab.
Correctly connect lever
sensor assembly cables
to main board assembly
connector J132.
Replace cover sensor
assembly.
Replace lever sensor
assembly.
9-3
Action
Reference
"4.8.3
Replacing
Cover Sensor
Assembly"
p.4-85
"4.3.3
Replacing
Main Board
Assembly"
p.4-29
"8.4
Lubrication/
Bonding"
p.8-7
"4.5.3
Replacing
Lever
Sensor" p.4-
54
"4.5.3
Replacing
Lever
Sensor" p.4-
54
"4.5.3
Replacing
Lever
Sensor" p.4-
54
"4.8.3
Replacing
Cover Sensor
Assembly"
p.4-85
"4.5.4
Replacing T
Fence" p.4-55
AP-74109 Rev 1.1