Canon iR1200 Series Service Manual page 239

Hide thumbs Also See for iR1200 Series:
Table of Contents

Advertisement

Chapter 9
 
[2]
F-9-71
3) Close the cartridge cover.
4) Disconnect the connector [2], and detach the
control panel [1].
To prevent damage to the flexible cable, be sure to lift
the
control
panel
disconnecting the connector [2].
[2]
F-9-72
MEMO:
To mount the control panel, turn it over as shown in
below figure, and connect the connector [1]; then, turn
back over [2] the control panel to facilitate the work.
9-26
[1]
slightly
as
shown
[1]
9.3.10.4 Removing the Front
Cover
1) Remove the cassette.
when
2) Remove the screw [1].
3) Free the 5 hooks [2], and detach the front cover [3].
[1]
9.3.10.5
Humidity Sensor
1) Disconnect the connector [1], and remove the screw
[2]; then, detach the humidity sensor [3].
[2]
[1]
F-9-73
[2]
[3]
F-9-74
Removing
the
0006-2881
[2]
0006-2882