Chapter 7
 
F-7-26
7.6.6.2 Removing the Manual
Feed Pickup Roller
1) Free the 2 hooks [1], and slide the 2 manual feed
pickup roller retainers [2] to the left and right.
[1]
[2]
F-7-27
2) Free the hook [1], and slide the manual feed pickup
roller [2] to the right to detach.
[2]
F-7-28
7-16
[1]
[2]
[1]
0006-3322
[1]
[1]

7.6.7 Manual Feed Tray sensor

7.6.7.1 Removing the Right
Cover
1) Slide the reader unit, and open the cartridge cover.
2) Open the manual feed tray.
3) Remove the 2 screws [1], and detach the right cover
[2].
F-7-29
7.6.7.2 Removing the Toner
Supply Cover
1) Open the toner supply cover [1].
2) Remove the 2 screws [2], and detach the cover [3].
3) Remove the toner supply cover [1].
[1]
F-7-30
To mount, fit a screw or the like with the gear [1] lifted
0006-3803
[1]
[2]
[1]
0006-3804
[2]
[3]
[2]