3) Close the cartridge cover.
4) Disconnect the connector [2], and detach the
control panel [1].
To prevent damage to the flexible cable, be sure to lift
the
control
panel
disconnecting the connector [2].
[2]
MEMO:
To mount the control panel, turn it over as shown in
below figure, and connect the connector [1]; then, turn
back over [2] the control panel to facilitate the work.
5.2.1.4 Removing the Front
Cover
1) Remove the cassette.
slightly
as
shown
[1]
F-5-6
[2]
[1]
F-5-7
0006-3187
2) Remove the screw [1].
3) Free the 5 hooks [2], and detach the front cover [3].
when
[1]
5.2.1.5 Removing the Cartridge
Cover
1) Free the hook [1].
2) Remove the 2 ribs [2], and detach the cartridge
cover [3].
5.2.1.6 Removing the Upper
Cover
1) Detach the part [1] holding the core and the part [2]
holding the cable.
2) Disconnect the 2 connectors [3] and remove the
core [4].
Chapter 5
[2]
[3]
[2]
F-5-8
0006-3188
[3]
[1]