Chapter 7
 
F-7-53
7.6.8.2 Removing the Toner
Supply Cover
1) Open the toner supply cover [1].
2) Remove the 2 screws [2], and detach the cover [3].
3) Remove the toner supply cover [1].
[1]
F-7-54
To mount, fit a screw or the like with the gear [1] lifted
in place the direction of the arrow as shown to stop;
then, attach the toner supply cover, and remove the
screw.
7-22
[1]
[2]
[1]
0006-3426
[2]
[3]
[2]
[1]
F-7-55
7.6.8.3 Removing the Control
Panel
1) Slide the reader unit, and open the cartridge cover.
2) Remove the screw [1], and slide the control panel
[2] to the left.
[2]
F-7-56
3) Close the cartridge cover.
4) Disconnect the connector [2], and detach the
control panel [1].
To prevent damage to the flexible cable, be sure to lift
0006-3427
[1]

Hide quick links: