Canon iR1200 Series Service Manual page 233

Hide thumbs Also See for iR1200 Series:
Table of Contents

Advertisement

Chapter 9
 
the
control
panel
disconnecting the connector [2].
[2]
F-9-46
MEMO:
To mount the control panel, turn it over as shown in
below figure, and connect the connector [1]; then, turn
back over [2] the control panel to facilitate the work.
F-9-47
9.3.8.5 Removing the Front
Cover
1) Remove the cassette.
2) Remove the screw [1].
3) Free the 5 hooks [2], and detach the front cover [3].
9-20
slightly
as
shown
[1]
[2]
[1]
0006-3143
when
[1]
9.3.8.6 Removing the Delivery
Cover
1) Remove the 3 screws [1], and detach the delivery
cover [2].
9.3.8.7
Controller PCB
1) Disconnect the 4 connectors [1] used to connect the
image processor PCB and the power supply unit.
2) Disconnect the connector [2] used to connect the
NCU PCB and the power supply unit.
3) Disconnect the connector [3], and free the harness
[4] from the harness guide [5].
[2]
[3]
F-9-48
[2]
[1]
F-9-49
Removing
the
DC
[2]
0006-3146
0006-3198

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir1570f

Table of Contents