6.20.2

Programming the RS 232 port

The RS 232 port is set-up for the connection of the Olympia/SERD TH 200 kitchen printer with a baud rate of
Example:
19,200 baud, for a data length of 7 bit, no parity and with 2 stop bits: status number 1 = 2, status number 2 =
20, status number 3 = 01.
1.
Set the key to PRG.
2.
Select programme number 23
(see Chapter 6.1.2).
Press the ┣CASH┫ key to confirm
3.
the selection.
Note:
Use the ┣↑┫ and ┣↓┫ keys to
4.
move to the [ ] CONNECTION
input area.
5.
Use the numeric keyboard to
enter the 1-digit status number,
e.g. 2.
Press the ┣CASH┫ key to confirm
6.
the input.
Use the ┣↑┫ and ┣↓┫ keys to
7.
move to the [ ] BAUDR-
DATALEN input area.
8.
Use the numeric keyboard to
enter the 2-digit status number 2,
e.g. 20.
Press the ┣CASH┫ key to confirm
9.
the input.
10. Use the ┣↑┫ and ┣↓┫ keys to
move to the [ ] PARITIY-STOPB
input area.
11. Use the numeric keyboard to
enter the 2-digit status number 3,
e.g. 01.
12. Press the ┣CASH┫ key to confirm
the input.
13. Conclude programming by press-
ing the ┣SUB-TOTAL┫ key.
Olympia
2011
Cash Register CM 940-F / 941-F / 942-F
Press the ┣CASH┫ key to switch between 5 different ports.
Only the RS 232 port, assigned to the first slot, can be
programmed.
Input
Page 87
Specifications subject to change without notice!
Display
COM PORT
COM-PORTA
RS232
[0 ]
CONNECTION
[11]
BAUDR-DATALEN
[00]
PARITY-STOPB
[ 0 ]
CONNECTION
[ 2 ]
CONNECTION
Save...!!
Please Continue...
[ 11 ]
BAUDR-DATALEN
[ 20 ]
BAUDR-DATALEN
Save...!!
Please Continue...
[ 00]
PARITY-STOPB
[ 01 ]
PARITY-STOPB
Save...!!
Please Continue...
1- 1=