Up-Down Button:
Momentarily pressing the up/down button activates the door. If an
out-of-balance condition causes the door to stop while opening or
reverses the door while closing, appling constant pressure to the up/
down button until the door is fully open or closed will allow the opener
to move the door in this condition until the problem is corrected.
See Troubleshooting. The up/down button (when unit is closed)
can be activated by pressing flip cover.
WARNING
A SEVERE OUT-OF-BALANCE CONDITION MUST BE CORRECTED
IMMEDIATELY. FAILURE TO MAKE ADJUSTMENTS/REPAIRS, COULD
RESULT IN SEVERE OR FATAL INJURY.
Light Button:
Momentarily pressing the light button turns on the light fixture. The
light fixture will remain on until either the light button is pressed again
or the door is activated. The light fixture automatically turns on with a
door activation and remains on for five minutes. Pressing the light
fixture button before the five minutes has elapsed will turn off the light
fixture. While the door is in motion, the light button functions identical
to the up/down button, stopping or reversing the door immediately.
Timer Button:
Momentarily pressing the timer button causes a delayed activation of a
stationary fully open door. The opener will signal seven beeps (approx.
8 seconds) then beep constantly for two seconds prior to closing the
door, allowing time to exit the garage. Pressing any button, except for
the profile button while the opener is beeping cancels the timer mode.
NOTE: The timer feature will only function with the door in the
full open position. Pressing the timer button with a stationary
door in any other position will cause the opener to beep four
times and the door will not be activated.
While the door is in motion, the timer button functions identical to the
up/down button, stopping or reversing the door immediately.
Slide Switch:
The slide switch has two positions: Normal, and Door lock.
Normal position:
Move the slide switch to normal position for all normal functions of the
opener. The normal position will cancel the door lock feature.
NOTE: When a slide switch move to the unlocked position is
accepted the opener will beep once.
Door Lock position:
If the door is stopped (fully open, fully closed or partially open) move
the slide switch to the door lock position to suspend all normal
functions of the opener. The opener will remain completely disabled
and non-operational in this mode. All wall stations, transmitters and
keyless entry units are ignored until the slide switch is moved to the
normal position. If the door is moving when the slide switch is moved
to the door lock position, the door lock mode is not activated and all
functions of the opener remain active.
NOTE: When a slide switch move to the locked position is
accepted the opener will beep twice.
You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com
27
Please Do Not Return This Product To The Store. Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need

Operating the Wireless Wall Station

Backlit LED Lights:
The Up/Down arrows backlit red LEDs blink intermittently to help you
locate the wall station in a dark garage. This blink rate can be changed
for longer battery life or can be turned off. The default blink rate is one
blink every two seconds. For longer battery life the blink rate can be
changed to blink once every four seconds. To change the blink rate,
remove the battery cover and remove one battery. Re-install the battery
and within 2 seconds, press the Light button. Re-install the battery
cover. For longest battery life, the blink can be turned off. To turn off
the blink, remove the battery cover and remove one battery.
Re-install the battery and within 2 seconds, press the pet button.
Re-install the battery cover.
NOTE: The wall station's arrow LEDs will light while any wall
station button remains pressed.
Pet Position:
Pressing the pet button opens a closed door to a preset position
between eight and thirty inches above the floor, allowing pets to enter
and exit the garage without the door being fully open. The door must
be fully closed to activate the pet open feature. Pressing the pet button
with a stationary door in the pet open position will cause the door to
close. Pressing the up/down button while the door is in the pet position
will cause the door to open. While the door is in motion, the pet button
functions identical to the up/down button, stopping or reversing the
door immediately. The pet feature allows for custom setting of the pet
position door height. See Customizing the Settings on page 30.
NOTE: A door in the "pet position" (open 8-30 inches) is not locked and
should not be used as a secured door position.
Profile Routine:
Press and hold the profile button for five (5) seconds will initiate
the "Install Routine". See Customizing the Settings on page 30.
NOTE: Refer to Step 28 for Wall Station programming instructions.
NOTE: The wall station arrows LEDs will light while any wall station
button remains pressed. See Maintenance section for battery
replacement.
Light Button
Slide Switch
Timer Button
Pet Button
Up/Down Button