Customizing The Settings; Custom Pet Position; Multi-Door Programming; Custom Upper Limits - Wayne-Dalton IDrive 3651-372 Installation Instructions And Owner's Manual

Table of Contents

Advertisement

Custom pet position:

Normal install routine sets the pet position to approximately 8 inches
above the ground. The pet opening height may be changed to open
anywhere between 8" and 30" above the ground. To change the
automatic pet opening height refer to the following procedure:
a. After completion of the normal install routine, with the door in the
closed position, place the disconnect handle in the manual operated
position.
Manually position the door to the desired pet opening height
(between 8" and 30" above ground) and return disconnect handle to
the motor operated position.
b. Move the slide switch from the NORMAL (Unlock) position to
the DOOR LOCK (Lock) position, wait 5 seconds, move switch back
to the NORMAL (Unlock) position. The opener will beep once. The
pet button is now programmed to automatically open the door to
this custom height.
NOTE: The opener will NOT accept programmed pet lock position if
door is below 8" or higher than 30".
NOTE: Activation of the normal install routine will reset the pet position
to the default 8" target height. For use of the pet button see Operation
section.

Multi-Door Programming:

Momentarily pressing the button programmed in the Transmitter
Programming Step activates the door. Other buttons can also be
programmed to activate different doors, for multi-door installations.
Each button or a combination of two buttons pressed simultaneously
can be programmed to activate a different door. Only one button at a
time can be programmed to activate a specific opener. The transmitter
LED will light while any transmitter button remains pressed.

Custom Upper Limits

Disconnect door and manually move it to the desired upper limit.
Reconnect door.
Press and hold the profile button for five (5) seconds. The
opener will beep twice, indicating the activation of the install routine.
The door will now move to the closed position. Then, the door will open
to the new upper limit.
Next, the door will go down to the closed position. Once this is
complete, the door limits are set and the installation is complete.
For more profile options go to page 20 and 21.
NOTE: Before performing custom upper limit, first profile must be done
from closed position.
You can reach us Toll Free at 1-888-827-3667 for Consumer Assistance or online at www.wayne-dalton.com
Please Do Not Return This Product To The Store Call Us Directly! Our Trained Technicians Will Answer Your Questions and/or Ship Any Parts You May Need

Customizing the Settings

NORMAL
DOOR LOCK
Up/Down Button
Up/Down Button
Pet Button
Profile Button
30