4
Tools Needed:
THE DOOR SHOULD BE ABLE TO CLOSE WITHOUT BINDING.
Electric Drill (With
Any binding during closing of the door could result in cables coming off the drums during the install routine. If this is the case, it
Clutch)
may be necessary to loosen the jamb brackets, to free the vertical wall angles which may have been deformed by over
tightening of the fasteners, preventing the smooth closing of the door. Also loosen the lag screw which attach the operator to
5mm (3/16") Drill Bit
the header. These can cause binding of the torque tube if the header is bowed. It will be necessary to re-tighten the fasteners,
using shims if necessary, to ensure proper alignment.
11mm (7/16") Wrench
Once these checks have been made, close the door and place emergency disconnect handle (1o) back to the motor operated
Tape Measure
position, as shown in FIG. 4.5, to reconnect the operator.
Screw Driver (Flat
Head)
Step Ladder
11mm (7/16") Hex
Head Driver
5
Tools Needed:
Locate a convenient place to mount the wall station (A12). Measure at least 1,5m up from floor and secure wall station base
(A12.1) two Philips head screws (A12.4). Use holes needed to ensure the base is securely mounted with both screws. If
Screw Driver (Phillips
fastening into drywall or concrete, proper anchors will need to be used.
Head)
IMPORTANT: Over tightening screws into wood could deform the plastic base and cause the circuit board not to snap into
place properly.
Insert bottom of circuit board (1l) behind bottom snap of wall station base. Pivot circuit board up until board snaps into place.
For best results, press on circuit board (A12.3) between both battery terminals (1n). Insert battery (A12.5) onto circuit board
being careful to match (+) positive battery marking with (+) positive circuit board marking. The LED's will light in sequence; then
turn off.
Align wall station cover/button assembly (A12.2) with base and circuit board. Press cover assembly over base until cover snaps
into place. A uniform seam between cover and base indicates a proper installation. Apply wall station reference label (A14) and
entrapment label (A3) in a convenient location next to the wall station.
Use mechanical fasteners, such as nails, staples, or thumbtacks, to attach wall station reference label and entrapment label to
surfaces to which adhesives will not adhere.
6
Locate and install the disconnect label (A11) on the wall next to the disconnect handle (A10) mounted on the right hand vertical
Tools Needed:
track (1m). Use mechanical fasteners, such as nails, staples, or thumbtacks, to attach the disconnect label to surfaces to which
adhesives will not adhere.
None
Back Hanging Horizontal Track and Spreader Bar and Manual Door
(See Diagram 4 on page 5 of Drawings of Installation, Use and Maintenance manual)
Wall Station Installation (If supplied, according to the model)
(see Diagram 5 on page 6 of Drawings of Installation, Use and Maintenance manual)
(see Diagram 6 on page 7 of Drawings of Installation, Use and Maintenance manual)
Testing - Continued