Telephone Test; Restore Default System Configuration; Soft Reset; Hard Reset - 2gig Technologies Go!Control Panel Installation & Programming Manual

Wireless security system
Hide thumbs Also See for Go!Control Panel:
Table of Contents

Advertisement

Go!Control Wireless Security System  |  Installation and Programming Guide

Telephone Test

Use this test to verify the land‐line connection from the 
panel's built‐in digital communicator and Central Station. 
At the Toolbox (3 of 3) screen, press the Telephone Test 
1
button.
At the Enter Master Code to Access Telephone Test 
2
screen, enter the master code.
The top area of the Telephone Test screen shows the 
Control Panel actions and the bottom area shows the 
results. 
Press the ↓ and ↑ arrows to review the ac ons and 
3
results. 
4
When complete, press OK to return to the Toolbox (3 of 
3) screen.
RESTORE DEFAULT SYSTEM
CONFIGURATION
You can restore the Control Panel settings back to its factory 
defaults. There are two (2) types of reset options: Soft and 
hard.

Soft Reset

A soft‐reset lets you select which settings to restore back to 
the factory defaults. 
To perform a soft‐reset:
At the Installer Toolbox screen, press the Restore 
1
Default button.
The Restore Default System Configuration screen 
appears. 
2
At the Restore Default System Configuration screen, 
select one or both checkboxes:
. Place a checkmark in this box to replace 
2a
Zones
data for ALL sensors with the factory default values.
AND/OR
Console. Place a checkmark in this box to replace all 
2b
of the programming answers with the factory 
defaults. This erases the user codes, resets the 
backlight timeout to five (5) minutes, and resets the 
Brightness/Volume settings. 
70
    Copyright ©  2014 Linear LLC
IMPORTANT: This action does not restore factory default 
settings for Z‐Wave questions Q79‐Q83. 

Hard Reset

A hard‐reset restores all of the programming settings back 
to the factory defaults. 
NOTE: Before performing a hard reset, Q44: Lock Installer 
Programming
must be set to option (1) or (2) and Q45: 
 
Lock Default Programming must be set to (0). See "Q44: 
Lock Installer Programming (0‐2)" on page 60.
To perform a hard reset:
Remove the Control Panel cover and completely 
1
disconnect all power to the Control Panel.
On the inside back of the Control Panel, plug in the 
2
backup battery. 
3
Press and hold down the Emergency 
buttons. 
Continue to hold down the Emergency 
4
buttons and then connect DC Power to the Control 
Panel. 
Release the buttons only after both the Emergency 
5
and Home buttons are lit and the Control Panel screen 
appears. 
and Home 
 and Home 
 