Q82: Z-Wave Door Locks Feature (0-1); Q83: Select Temperature Display Units (0-1); Q84: Services Require Master Code (0 To 1); Q85: Master User Access To Z-Wave Toolbox (0-1) - 2gig Technologies Go!Control Panel Installation & Programming Manual

Wireless security system
Hide thumbs Also See for Go!Control Panel:
Table of Contents

Advertisement

Q82: Z-Wave Door Locks Feature (0-1)
DEFAULT: (0) Disabled
Display of the Home Service's Door Locks button can be 
enabled or disabled. This programming question only 
functions if the Z‐Wave feature enable question Q79: Z‐
Wave Feature is set to (2) or (3).
The default setting (0) Disabled hides the Door 
Locks button.
To display the Door Locks button, select (1) 
Enabled.
Q83: Select Temperature Display Units
(0-1)
DEFAULT: (0) Degrees 
Fahrenheit
The Home Service's Z‐Wave thermostat display screens can 
show the temperature in degrees Fahrenheit or degrees 
Celsius.
NOTE: This programming question only functions if Q79: Z‐
Wave Feature is set to (2) or (3) and Q81: Z‐Wave 
Thermostats Feature is set to (1) Enabled.
The default setting is (0) Degrees Fahrenheit.
To change the setting, select (1) Celsius.
NOTE: The setting you select here also changes the display 
units shown on the weather forecast on the Control 
Panel's Home screen.
Q84: Services Require Master Code (0 to
1)
DEFAULT: (0) Disabled
The Services button can be configured to require the use of 
the master user code to access Services.
The default setting (0) Disabled overrides the 
requirement to enter a master user code to access the 
Services menu.
To require the use of the master user code to access the 
Services menu, select (1) Enabled.
When enabled then the master user code is required to 
access the Services and the Z‐Wave device configurations. 
This keeps unauthorized users from being able to change Z‐
Wave settings, such as temperature, lights and locks.
Q85: Master User Access to Z-Wave
Toolbox (0-1)
DEFAULT: (0) Disabled
The Z‐Wave Toolbox menu can be set to require the use of 
the master user code or the installer code. By default, the 
installer code is required for users to access the Z‐Wave 
Toolbox.
The default setting (0) Disabled requires users to enter 
the installer code to access the Z‐Wave Toolbox menu 
and all of its features, including the Advanced Toolbox.
To require the use of the master user code or the 
installer code to access the Z‐Wave Toolbox menu, 
select (1) Enabled.
NOTE: When (1) Enabled, the Installer code will still be 
required to access the Advanced Toolbox menu. This 
prevents end users from adding or removing Z‐Wave 
devices.
Q86: Disable Siren After Two-Way Audio
(0-1)
DEFAULT: (0) Disabled
This setting enhances system operation in personal 
emergency applications and also provides the dealer with 
the option of the siren sounding until the bell cut off or to 
the end of a two‐way‐voice session.
The default setting (0) Disabled will cause the siren to 
resume after two‐way audio (if the bell cut off timer has 
not expired).
(1) Enabled will cause the siren to shut off after a two‐
way audio session.
Q87: Keyfob/Remote Arming Mode on
System Not Ready (0-2)
DEFAULT: (0) Auto Bypass with Zone Participation on 
Restore
This setting controls how the system will react when there 
are open sensors and the system is armed remotely.
The default setting (0) Disabled will automatically 
bypass all sensors that are open when the system is 
armed remotely. If a sensor restores while the system is 
armed, the sensor's bypass will be removed, and the 
sensor will be ready to trigger an alarm.
To automatically bypass all sensors that are open when 
the system is armed remotely, and keep all bypasses in 
place during the arming cycle, even if a sensor restores, 
select (1) Auto‐Bypass.
To prevent arming remotely when any sensor is open, 
select (2) Arm Only When Ready.
Q88: Siren Mode (0-1)
DEFAULT: (0) Sound for Burglary and Fire/CO 
This setting selects which alarm types will activate a Z‐Wave 
siren linked to the system.
The default setting (0) Sound for Burglary and Fire/CO 
causes a Z‐Wave siren to sound during burglary and Fire/CO 
alarms.
To have a Z‐Wave siren sound only during burglary 
alarms, select (1) Sound for Burglary Only.
Q89: Allow Backlight Always On (Demo
Mode) (0-1)
NOTE: May cause ghost/image retention.
DEFAULT: (0) Disabled
When set to (1) Enabled the customer can program the 
"always on" option for backlight programming. Due to a 
small percentage of image "ghosting" on the panel 
(because the backlight never goes off), this question was 
been created but has been defaulted to (0) Disabled.
Copyright © 2014 Linear LLC