INTRODUCTION

ABOUT THIS GUIDE

This guide provides distributors, dealers, and authorized installation personnel with information about installing, testing, 
and maintaining the 2GIG Go!Control system. 2GIG by Linear products are not sold directly to consumers and can only be 
obtained from authorized distribution channels. For a list of authorized distributors, visit: http://www.2gig.com/find‐a‐
distributor.

ABOUT THE 2GIG GO!CONTROL SYSTEM

Depending on the options set during the installation, the 2GIG Go!Control system has the ability to provide three forms of 
protection: burglary, fire, and emergency, The system consists of the 2GIG Control Panel, wireless sensors for perimeter and 
interior burglary protection, and wireless smoke and carbon monoxide detectors. In addition, optional remote control key 
fobs, wireless panic buttons, and keypads may also be installed.
The system monitors all protection sensor types (a.k.a., "zones") and the system's status. The Control Panel displays 
monitoring information and controls the alarm siren. The system can also be setup to send alarm and status reports to a 
Central Station and has the capability for two (2)‐way voice communications with the Remote Service Provider (RSP). 
When a security system is installed, insurers may offer discounts on the homeowners' or renters' insurance policy. Although 
the requirements and discount credits vary for each different insurer, users can generally save money as the level of 
protection increases. It is recommended that you inform the end user to check with their insurance agent to determine if 
the insurer has specific requirements and/or offers any discount(s).

IMPORTANT INFORMATION

The 2GIG Go!Control security system conforms to the Security Industry Alarm Coalition's ANSI/SIA CP‐01: Control Panel 
Standard‐Features for False Alarm Reduction. It also meets the residential security system certification criteria for the ETL 
Listed Mark. 
The recommended storage temperature for all Control Panels is ‐10°C to 60°C (14°F to 140°F). For optimal Control Panel 
use, operation temperature is 0°C to 49°C (32°F to 120°F). No altitude range limitations have been reported while 
transporting Control Panel.

Installing the System in Residential Settings

When installing the system in a residential setting, be aware of the following:
Fire warning systems must be installed in accordance with national codes. In the United States, fire warning 
systems must be installed in accordance with ANSI/NFPA 72 National Fire Alarm and Signaling Code and ANSI/NFPA 
70 National Electric Code.
A permit may be required for this alarm system. Some cities and municipalities may require an alarm system 
permit. Before installing this system, always ensure that you are in compliance with any national, regional, and local 
laws, rules, and/or guidelines.
This system is intended for use with approved‐model smoke alarms only. For use as a smoke alarm system, there 
must be at least one (1) smoke alarm programmed into the Control Panel and must use only approved model smoke 
alarms. Visit the 2GIG Dealer Web Site at dealer.2gig.com.
Failure to follow ETL requirements voids this system's ETL Listed mark. Failure to install the Control Panel and 
accessories in accordance with the ETL requirements documented in this manual voids its ETL Listed Mark.

Installing the System in Commercial Settings

When installing the system in a commercial setting, be aware of the following:
The system cannot be used for fire protection in commercial settings. In a commercial setting, it is important to 
know that the Control Panel is neither designed nor intended for use as a fire protection system. 
The system is intended only for security protection of premises. In a commercial setting, this system is only 
intended for protection of commercial premises, such as a mercantile or office. It is neither designed nor intended 
to protect commercial bank vaults. 
A permit may be required for this alarm. Some cities and municipalities may require an alarm system permit. 
Before installing this system, always ensure that you are in compliance with any national, regional, and local laws, 
rules, and/or guidelines.
Copyright © 2014 Linear LLC
5