Q48: Download CSID (6 Digits)
DEFAULT: 000000
The system supports a six (6)‐digit CSID code that is used for 
remote telephone programming of the Control Panel. This 
code is verified when the Control Panel connects with the 
downloading software. If the CSID code doesn't match the 
downloading software, the Control Panel will deny the 
connection.
The CSID code can be entered manually with this 
programming question.
If this field is left with the default (000000), the first 
time the downloading software connects with the 
Control Panel, the field will be filled with the 
software's CSID.
Q49: Programming Mode Entry Reports
to CS (0-1)
DEFAULT: (0) Disabled
A report can be sent to the Central Station any time installer 
programming mode is entered and exited.
The default setting (0) Disabled prevents reporting 
programming mode entry and exit.
To report programming mode entry and exit, select 
(1) Enabled.
NOTE: This report can only be sent through the telephone 
dialer. It is not supported through the GSM (Cellular) 
Radio Module.
Q50: Trouble Reports to CS (0-1)
DEFAULT: (1) Enabled
Trouble reports can be sent to the Central Station when any 
sensor trouble condition occurs.
The default setting (1) Enabled allows reporting 
sensor trouble conditions.
To not report sensor trouble conditions, select (0) 
Disabled.
NOTE: This setting does not affect trouble reports caused 
by Control Panel conditions, only trouble reports caused 
by sensors.
Q51: Manual Bypass Reports to CS (0-1)
DEFAULT: (0) Disabled
Manual bypass reports can be sent to the Central Station 
when any sensor has been manually bypassed by the user.
The default setting (0) Disabled prevents sending 
manual bypass reports.
To allow sending manual bypass reports, select (1) 
Enabled.
Q52: AC Loss Reports to CS (0-1)
DEFAULT: (1) Enabled
AC power loss reports can be sent to the Central Station if 
the Control Panel loses AC power.
The default setting (1) Enabled allows AC power loss 
reports.
To turn off AC power loss reports, select (0) 
Disabled.
NOTE: The AC power will have to be absent from the 
Control Panel for the time set by programming question 
Q38 before the AC power loss trouble alert 
displayed (the default is 10 minutes). If programming 
question Q39 is enabled, the actual AC power loss 
report will occur at a random time of up to four hours 
after the AC power loss trouble alert 
NOTE: The Control Panel's AC power icon displays the 
power status immediately. A red "X" over the icon 
indicates no AC power.
Q53: System Low Battery Reports to CS
(0-1)
DEFAULT: (1) Enabled
Low battery reports can be sent to the Central Station if the 
Control Panel's battery tests low.
The default (1) Enabled allows Control Panel low 
battery reports.
To turn off Control Panel low battery reports, select 
(0) Disabled.
Q54: RF Low Battery Reports to CS (0-1)
DEFAULT: (1) Enabled
Sensor low battery reports can be sent to the Central 
Station if a sensor battery tests low and sends a low battery 
transmission to the Control Panel.
The default setting is (1) Enabled and allows the 
system to send low battery reports for sensors. 
To turn this feature OFF, select (0) Disabled.
Q55: Opening Reports to CS (0-1)
DEFAULT: (0) Disabled
Opening reports can be sent to the Central Station each 
time the system is disarmed. The user or key fob number is 
indicated in the opening report.
The default setting (0) Disabled prevents opening 
reports.
To allow opening reports, select (1) Enabled.
Q56: Closing Reports to CS (0-1)
DEFAULT: (0) Disabled
Closing reports can be sent to the Central Station each time 
the system is armed. The user or key fob number is 
indicated in the closing report. If Quick Arming is enabled, 
User #0 is indicated for the closing report.
The default setting (0) Disabled prevents closing 
reports.
To allow closing reports, select (1) Enabled.
Copyright © 2014 Linear LLC