Q90: Energy Feature (0 to 1)

DEFAULT: (0) Disabled and Hidden
Select (1) Disabled but Visible to show but not activate the 
energy features. You can also select (2) Enabled to turn the 
energy feature ON. 

Q91: Radio Modem Supplier

DEFAULT: (0) None
NOTE: If you enable Q44: Select Lock Installer 
Programming, you will not be able to change this 
setting.
Select the option that corresponds to the appropriate 
supplier. Options include:
(1) Radio Modem Supplier 1. Select this option if 
the radio modem is supplied by Alarm.com.
(2) Radio Modem Supplier 2. Select this option if 
the radio modem is supplied by the Telular 
Corporation.

Q92: Network Device (0 to 1)

DEFAULT: (0) None
When enabled, the (1) Go!Bridge option provides the 
installer to program the Go!Bridge IP Communicator 
settings into the Control Panel.

Q: Port # (1 to 8)

DEFAULT: (1) Port 1
NOTE: Typically, you will skip this question unless 
additional programming is required.
Enter the port number for the backend server.

Q: Used (0 to 1)

DEFAULT: (0) Disabled
NOTE: Typically, you will skip this question unless 
additional programming is required.
It is recommended that you always select the default 
setting (0) Disabled. If you choose (1) Enabled, you will be 
prompted to enter the port value as shown in the next 
question. 

Q: Port Value (0 to 65535)

DEFAULT: (0) Disabled
NOTE: Typically, you will skip this question unless 
additional programming is required.
It is recommended that you always select the default 
setting (0) Disabled.
However, if you select (1) Enabled in Q: Select Used (0 to 1), 
enter the port value. The port value is the port number that 
must be specified to communicate over the Transmission 
Control Protocol (TCP). Port numbers can range from 0 to 
65535. 

Q: Port Forward IP Address

DEFAULT: 000.000.000.000
Typically, you will simply accept the default IP Address value 
that appears.
66
    Copyright ©  2014 Linear LLC
Q93: Enter Broadband Network Failure
Time (1-255)
DEFAULT: 30 Minutes
NOTE: The Go!Bridge IP Communicator must be installed to 
use this function.
Sets the amount of time required for triggering a trouble 
condition if the system detects that the broadband network 
has lost its connection. After the connection has been 
restored, the trouble condition clears.
The default failure detection setting is 30 minutes.
To choose a different failure detection time, enter 
the number of minutes between 1‐255.
Q94: Select Broadband Network Failure
Causes Trouble (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to 
use this function.
Selects whether the Control Panel will sound and display a 
trouble alert if the Go!Bridge IP Communicator loses its 
broadband connection. The trouble alert can be silenced by 
the user at the Control Panel (broadband trouble is logged 
regardless of this setting). When the broadband connection 
is restored, the trouble indications automatically clear.
The default setting (1) Enabled allows Go!Bridge 
network failure trouble indications.
To turn off Go!Bridge trouble indications, select (0) 
Disabled.
Q95: Select Broadband Network Failure
Reports (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to 
use this function.
If the Go!Bridge IP Communicator loses its broadband 
connection, the Control Panel can report the fault. 
The default setting is (1) Enabled which turns 
broadband network failure reporting ON. 
To turn broadband network failure reporting OFF, 
select (0) Disabled. 