Go!Control Wireless Security System | Installation and Programming Guide
Q90: Energy Feature (0 to 1)
DEFAULT: (0) Disabled and Hidden
Select (1) Disabled but Visible to show but not activate the
energy features. You can also select (2) Enabled to turn the
energy feature ON.
Q91: Radio Modem Supplier
DEFAULT: (0) None
NOTE: If you enable Q44: Select Lock Installer
Programming, you will not be able to change this
setting.
Select the option that corresponds to the appropriate
supplier. Options include:
•
(1) Radio Modem Supplier 1. Select this option if
the radio modem is supplied by Alarm.com.
•
(2) Radio Modem Supplier 2. Select this option if
the radio modem is supplied by the Telular
Corporation.
Q92: Network Device (0 to 1)
DEFAULT: (0) None
When enabled, the (1) Go!Bridge option provides the
installer to program the Go!Bridge IP Communicator
settings into the Control Panel.
Q: Port # (1 to 8)
DEFAULT: (1) Port 1
NOTE: Typically, you will skip this question unless
additional programming is required.
Enter the port number for the backend server.
Q: Used (0 to 1)
DEFAULT: (0) Disabled
NOTE: Typically, you will skip this question unless
additional programming is required.
It is recommended that you always select the default
setting (0) Disabled. If you choose (1) Enabled, you will be
prompted to enter the port value as shown in the next
question.
Q: Port Value (0 to 65535)
DEFAULT: (0) Disabled
NOTE: Typically, you will skip this question unless
additional programming is required.
It is recommended that you always select the default
setting (0) Disabled.
However, if you select (1) Enabled in Q: Select Used (0 to 1),
enter the port value. The port value is the port number that
must be specified to communicate over the Transmission
Control Protocol (TCP). Port numbers can range from 0 to
65535.
Q: Port Forward IP Address
DEFAULT: 000.000.000.000
Typically, you will simply accept the default IP Address value
that appears.
66
Copyright © 2014 Linear LLC
Q93: Enter Broadband Network Failure
Time (1-255)
DEFAULT: 30 Minutes
NOTE: The Go!Bridge IP Communicator must be installed to
use this function.
Sets the amount of time required for triggering a trouble
condition if the system detects that the broadband network
has lost its connection. After the connection has been
restored, the trouble condition clears.
•
The default failure detection setting is 30 minutes.
•
To choose a different failure detection time, enter
the number of minutes between 1‐255.
Q94: Select Broadband Network Failure
Causes Trouble (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to
use this function.
Selects whether the Control Panel will sound and display a
trouble alert if the Go!Bridge IP Communicator loses its
broadband connection. The trouble alert can be silenced by
the user at the Control Panel (broadband trouble is logged
regardless of this setting). When the broadband connection
is restored, the trouble indications automatically clear.
•
The default setting (1) Enabled allows Go!Bridge
network failure trouble indications.
•
To turn off Go!Bridge trouble indications, select (0)
Disabled.
Q95: Select Broadband Network Failure
Reports (0 to 1)
DEFAULT: (1) Enabled
NOTE: The Go!Bridge IP Communicator must be installed to
use this function.
If the Go!Bridge IP Communicator loses its broadband
connection, the Control Panel can report the fault.
•
The default setting is (1) Enabled which turns
broadband network failure reporting ON.
•
To turn broadband network failure reporting OFF,
select (0) Disabled.