Programming Question Table - 2gig Technologies Go!Control Panel Installation & Programming Manual

Wireless security system
Hide thumbs Also See for Go!Control Panel:
Table of Contents

Advertisement

PROGRAMMING QUESTION TABLE
Q#
Question
Q1
Select RF Sensor # (01 to 48)
Select RF Sensor # Type
Select RF Sensor # Equipment Type
Select RF Sensor # Equipment Code
Enter RF Sensor # Other Equipment Code (0‐9999)
Enter RF Sensor # Serial Number (7 digits)
Select RF Sensor # Equipment Age (0 to 1)
Select RF Sensor # Loop Number (1 to 3)
Select RF Sensor # Dialer Delay (0 to 1) 
Construct RF Sensor # Voice Descriptor
Select RF Sensor # Reports (0 to 1)
Select RF Sensor # Supervised (0 to 1)
Select RF Sensor # Chime (0 to 13)
Q2
Select Wired Sensor # (1 to 2)
Select Wired Sensor # Type
Select Wired Sensor # Equipment Age (0 to 1)
Select Wired Sensor # Normal State (0 to 3)
Select Wired Sensor # Dialer Delay (0 to 1)
Construct Wired Sensor # Voice Descriptor (0 to 1) ‡
Select Wired Sensor # Reports (0 to 1)
Select Wired Sensor # Chime (0 to 13)
Q3
Select Fob # (1 to 8)
 Select Fob # Used (0 to 1)
 Select Fob # Equipment Code (0000)
 Enter Fob # Other Equipment Code (0 to 9999)
 Enter Fob # Serial Number (7 digits)
 Select Fob # Equipment Age (0 to 1)
 Select Fob # Emergency Key (0 to 4)
 Select Fob # Key 2 Can Disarm (0 to 1)
 Construct Fob # Voice Descriptor
 Select Fob # Arm No Delay (0 to 1)
 Select Fob # Key 4 Output (0 to 2)
Q4
Select RF Keypad # (1 to 4)
Select RF Keypad # Used (0 to 1)
Select RF Keypad # Equipment Code
Enter RF Keypad # Other Equipment Code (0 to 9999)
Enter RF Keypad # Serial Number (7 digits)
Select RF Keypad # Emergency Age (01)
Select RF Keypad # Emergency Keys (01)
Construct RF Keypad # Voice Descriptor
Q5
Enter Exit Delay, in Seconds (45 to 120)
Q6
Enter Entry Delay 1, in Seconds (30 to 240)
Q7
Enter Entry Delay 2, in Seconds (30 to 240)
Q8
Select Dialer (0 to 1)
Q9
Enter Dialing Prefix (0 to 4 digits)
Q10
Enter Call Waiting Disable Code (0 to 6 digits)
Q11
Enter CS #1 Phone Number (0 to 25 digits)
Q12
Enter CS #1 Account Number (4 digits)
Q13
Select Two‐Way Voice (0 to 2)
Q14
Select Silent Panic/Burglary Listen Only (1 to 1)
Q15
Select Dialing Type (0 to 1)
Q16
Select Police Emergency Key (0 to 2)
Q17
Select Fire Emergency Key (0 to 1)
Default
(00) Unused
Varies by RF sensor type
Only shown for some sensor types
(0000) Other
0
NOTE: Only shown if (0000) Other is selected as the RF Sensor # 
Equipment Code
0000000
(0) New
Varies with sensor model selected
(1) Enabled‡
(2) Disabled (for Fire and CO only)
No Default Setting
(1) Enabled
(1) Enabled
(0) Disabled
(00) Unused
(0) New
(0) Not Used
(1) Enabled‡
No default
(1) Enabled
(0) Disabled
(0) Unused
(0000) Other
0
NOTE: Only shown when (0000) other is selected as the Fob # 
Equipment Code
0000000
(0) New
(0) Disabled
(1) Enabled
Keyfob #
(0) Disabled
(0) Disabled
(0) Unused
(0000) Other
0
NOTE: Only shown if (0000) Other is selected as the RF Keypad # 
Equipment Code
0000000
(0) New
(1) Enabled
Keypad #
60 seconds‡
30 seconds‡
45 seconds‡
(0) disabled
No default
No default‡
No default
No default
(1) Stay Online
(1) Enabled
(0) Touch Tone
(1) Audible
(1) Audible