Q11: CS #1 Phone Number (0-25 Digits)
DEFAULT: No Default
Enter the telephone number for the Central Station #1. You
can enter up to 25 digits.
•
Enter the Central Station #1 telephone number.
•
Access the pound and star symbols by pressing the
Shift button. The P button adds a three (3)‐second
pause to the dialing.
NOTE: If a second Central Station telephone number is
programmed with question Q41: CS #2 Account Number,
the Control Panel alternates between the two Central
Station telephone numbers. After two failed telephone
dialing attempts, the Control Panel attempts to connect
using the GSM (Cellular) Radio Module if it is installed. If
the GSM (Cellular) Radio Module is not installed, the
Control Panel will make eight (8) dialing attempts.
Q12: CS #1 Account Number (4 Digits)
DEFAULT: No Default
Enter the account number for Central Station #1. This
number is always four (4) digits and can include some alpha
characters.
•
Enter the four (4) digit for the Central Station #1
account number.
•
The Shift button accesses B, C, D, E, and F characters.
Q13: 2-Way Voice (0-2)
DEFAULT: (1) Stay On Line
The Control Panel supports two (2)‐way voice
communications between the subscriber and the Central
Station operator over the telephone line or the GSM
(Cellular) Radio Module (if installed) after an alarm has
been reported.
•
The (1) Stay On Line allows two (2)‐way audio over the
telephone line or cell radio.
•
Selecting (2) Stay On Line, Including Fire and CO Alarms
allows 2‐way audio over the telephone line or cell radio
during fire and CO alarms.
•
To turn off the two (2)‐way audio feature OFF, select (0)
Disabled.
When the Control Panel connects with the operator, it will
beep once per second (every 6 seconds with a cell radio
connection). The beep alternates between two tones and
indicates the Control Panel is waiting for a session
command. If the operator fails to issue a command within
one (1) minute (or three (3) minutes if using the cell radio
connection), the call is terminated. Once the operator
presses a command option, the beeps will stop and a five
(5)‐minute audio session will start (or three (3)‐minute
audio session if using the cell radio connection).
When two (2)‐way voice communications have been
established, the Central Station operator can use the
following telephone keys to control the communications.
Each time the operator uses a command key, the session is
extended for five additional minutes (three minutes with a
cell radio connection). During the last minute of
communications, the system beeps two (2) times every 15
seconds to indicate that time is running out.
•
Press 1 to enable Talk mode one (1)‐way
communication from the Central Station to the
premises and allows the operator to talk.
•
Press 2 to enable VOX mode two (2)‐way
communications from the Central Station to the
premises.
•
Press 3 to enable Listen mode one (1)‐way
communication from the premises to the Central
Station.
•
Press 7 to extend the session five (5) minutes
without changing the mode of operation.
•
Press 9 to end the audio session an terminate the
call.
Q14: Silent Panic/Burglary Listen Only
DEFAULT: (1) Enabled
The Control Panel supports audio listen‐in of the subscriber
premises from the Central Station over the telephone line
after a silent panic (police emergency), silent burglary, or
duress alarm has been reported.
•
The default setting (1) Enabled allows the Central
Station to use listen‐in over audio after a silent panic,
silent burglary, or duress alarm.
•
This option is permanently set and cannot be disabled.
Q15: Dialing Type (0-1)
DEFAULT: (0) Touch Tone
The digital communicator uses tones or pulses.
•
The default setting (0) Touch Tone is for Dual‐Tone
Multi‐Frequency (DTMF) dialing.
•
For rotary dialing, select (1) Pulse.
Q16: Police Emergency Key (0-2)
DEFAULT: (1) Audible
The Control Panel's panic emergency button action can be
programmed. The panic emergency button is displayed by
pressing the
button.
•
The default (1) Audible allows the panic emergency
button to sound an audible alarm.
•
For silent activation, select (2) Silent Panic.
•
To disable and not display the panic emergency
button, select (0) Disabled.
NOTE: Setting this programming question for (2) Silent
Panic makes the Police button on all RF keypads silent
also.
Q17: Fire Emergency Key (0-1)
DEFAULT: (1) Audible
The Control Panel's fire emergency button can be enabled
or disabled. The fire emergency button is displayed by
pressing the Control Panel's
•
The default setting (1) Audible allows the fire
emergency button to sound an audible alarm.
•
To disable and not display the fire emergency
button, select (0) Disabled.
Copyright © 2014 Linear LLC
Control Panel Programming
button.
55
Need help?
Do you have a question about the Go!Control Panel and is the answer not in the manual?