Q11: CS #1 Phone Number (0-25 Digits)
DEFAULT: No Default
Enter the telephone number for the Central Station #1. You 
can enter up to 25 digits.
Enter the Central Station #1 telephone number.
Access the pound and star symbols by pressing the 
Shift button. The P button adds a three (3)‐second 
pause to the dialing.
NOTE: If a second Central Station telephone number is 
programmed with question Q41: CS #2 Account Number, 
the Control Panel alternates between the two Central 
Station telephone numbers. After two failed telephone 
dialing attempts, the Control Panel attempts to connect 
using the GSM (Cellular) Radio Module if it is installed. If 
the GSM (Cellular) Radio Module is not installed, the 
Control Panel will make eight (8) dialing attempts.
Q12: CS #1 Account Number (4 Digits)
DEFAULT: No Default
Enter the account number for Central Station #1. This 
number is always four (4) digits and can include some alpha 
characters.
Enter the four (4) digit for the Central Station #1 
account number.
The Shift button accesses B, C, D, E, and F characters.
Q13: 2-Way Voice (0-2)
DEFAULT: (1) Stay On Line
The Control Panel supports two (2)‐way voice 
communications between the subscriber and the Central 
Station operator over the telephone line or the GSM 
(Cellular) Radio Module (if installed) after an alarm has 
been reported.
The (1) Stay On Line allows two (2)‐way audio over the 
telephone line or cell radio.
Selecting (2) Stay On Line, Including Fire and CO Alarms 
allows 2‐way audio over the telephone line or cell radio 
during fire and CO alarms.
To turn off the two (2)‐way audio feature OFF, select (0) 
Disabled.
When the Control Panel connects with the operator, it will 
beep once per second (every 6 seconds with a cell radio 
connection). The beep alternates between two tones and 
indicates the Control Panel is waiting for a session 
command. If the operator fails to issue a command within 
one (1) minute (or three (3) minutes if using the cell radio 
connection), the call is terminated. Once the operator 
presses a command option, the beeps will stop and a five 
(5)‐minute audio session will start (or three (3)‐minute 
audio session if using the cell radio connection).
When two (2)‐way voice communications have been 
established, the Central Station operator can use the 
following telephone keys to control the communications. 
Each time the operator uses a command key, the session is 
extended for five additional minutes (three minutes with a 
cell radio connection). During the last minute of 
communications, the system beeps two (2) times every 15 
seconds to indicate that time is running out.
Press 1 to enable Talk mode one (1)‐way 
communication from the Central Station to the 
premises and allows the operator to talk.
Press 2 to enable VOX mode two (2)‐way 
communications from the Central Station to the 
premises.
Press 3 to enable Listen mode one (1)‐way 
communication from the premises to the Central 
Station.
Press 7 to extend the session five (5) minutes 
without changing the mode of operation.
Press 9 to end the audio session an terminate the 
call.
Q14: Silent Panic/Burglary Listen Only
DEFAULT: (1) Enabled
The Control Panel supports audio listen‐in of the subscriber 
premises from the Central Station over the telephone line 
after a silent panic (police emergency), silent burglary, or 
duress alarm has been reported.
The default setting (1) Enabled allows the Central 
Station to use listen‐in over audio after a silent panic, 
silent burglary, or duress alarm.
This option is permanently set and cannot be disabled.
Q15: Dialing Type (0-1)
DEFAULT: (0) Touch Tone
The digital communicator uses tones or pulses.
The default setting (0) Touch Tone is for Dual‐Tone 
Multi‐Frequency (DTMF) dialing.
For rotary dialing, select (1) Pulse.
Q16: Police Emergency Key (0-2)
DEFAULT: (1) Audible
The Control Panel's panic emergency button action can be 
programmed. The panic emergency button is displayed by 
pressing the 
 button.
The default (1) Audible allows the panic emergency 
button to sound an audible alarm.
For silent activation, select (2) Silent Panic.
To disable and not display the panic emergency 
button, select (0) Disabled.
NOTE: Setting this programming question for (2) Silent 
Panic makes the Police button on all RF keypads silent 
also.
Q17: Fire Emergency Key (0-1)
DEFAULT: (1) Audible
The Control Panel's fire emergency button can be enabled 
or disabled. The fire emergency button is displayed by 
pressing the Control Panel's 
The default setting (1) Audible allows the fire 
emergency button to sound an audible alarm.
To disable and not display the fire emergency 
button, select (0) Disabled.
Copyright © 2014 Linear LLC
Control Panel Programming
 button.
55

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Go!Control Panel and is the answer not in the manual?

Table of Contents

Save PDF