Q34: Cross Sensor Timeout, in Seconds
(10-120)
DEFAULT: 10 Seconds
The cross sensor timeout is the maximum period of time 
allowed between violation of sensors 47 and 48 that will 
trigger an alarm. If both sensors are violated within this 
time period, an alarm will be triggered. If both sensors are 
not violated within this time period, an alarm will not be 
triggered.
NOTE: Cross sensor verification must be enabled with 
Q33: Cross Sensor 47‐48 for this feature to function.
The default setting for the cross sensor timeout is 
10 seconds.
To change the timeout duration, enter a valued 
between 11 to 120 seconds.
Q35: Abort Window Dialer Delay (0-2)
DEFAULT: (1) 30 Seconds
The default minimum setting for ANSI/SIA CP‐01 compliance 
is 30 seconds. 
The delay time can be increased to 45 seconds without 
affecting ANSI/SIA CP‐01 compliance only if the 
combination of Q35 and Q6 or Q7 does not exceed one (1) 
minute.
NOTE: The dialer delay can be disabled for each sensor 
without affecting ANSI/SIA CP‐01 compliance. See "RF 
Sensor Programming Questions" on page 42.
The dialer (digital communicator) delays calling the Central 
Station to allow the user enough time to cancel a false 
alarm before it is reported.
The default setting is (1) 30 Seconds.
To change the setting, select (0) 15 Seconds or (2) 
45 Seconds.
Q36: Burglary Bell Cutoff (0 to 4)
DEFAULT: (0) 4 Minutes 
When a burglary alarm is triggered, the bell will sound until 
the burglary bell cutoff time expires.
The default setting for the burglary bell cutoff is (0) 
4 Minutes.
To change the cutoff time, select an option below.
Burglary Bell Cutoff Time
(0) 4 Minutes
(1) 8 Minutes
(2) 12 Minutes
(3) 16 Minutes
(4) Unlimited
NOTE: The 24‐hour Auxiliary Alarm Zone (08) does not 
follow the burglary bell cutoff time and will sound the 
Control Panel's local alarm until a User Code is entered. 
The Auxiliary Alarm Zone does not trigger the external 
siren (if used).
58
    Copyright ©  2014 Linear LLC
Q37: Fire Bell Cutoff (0-4)
DEFAULT: (0) 4 Minutes
When a fire alarm is triggered, the bell sounds until the fire 
bell cutoff time expires.
The default setting (0) 4 Minutes sets the burglary 
bell cutoff to four (4) minutes.
To change the fire bell cutoff time, select an option 
below
Fire Bell Cutoff Time
(0) 4 minutes
(1) 8 minutes
(2) 12 minutes
(3) 16 minutes
(4) Unlimited
Q38: Time to Detect AC Loss, in Minutes
(0-30)
DEFAULT: (10) 10 Minutes
When AC power is lost, they system displays a power loss 
alert 
 after the specified time length. When power is 
restored, the alert is automatically cleared after one (1) 
minute.
The default detection timer for displaying the alert 
message is (10) 10 Minutes.
To change the detection timer, enter a value 
between 0 to 30 minutes.
NOTE: After the AC power alert 
the AC power loss report or AC power restore report 
can be sent to the Central Station immediately, or at a 
random time, see Q39: Random AC Loss Report Time.
NOTE: The Control Panel's AC Power Icon immediately 
displays the power status. See "AC Power On/OFF" on 
page 29.
 is displayed or clears, 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Go!Control Panel and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents

Save PDF