Go!Control Wireless Security System | Installation and Programming Guide
Q34: Cross Sensor Timeout, in Seconds
(10-120)
DEFAULT: 10 Seconds
The cross sensor timeout is the maximum period of time
allowed between violation of sensors 47 and 48 that will
trigger an alarm. If both sensors are violated within this
time period, an alarm will be triggered. If both sensors are
not violated within this time period, an alarm will not be
triggered.
NOTE: Cross sensor verification must be enabled with
Q33: Cross Sensor 47‐48 for this feature to function.
•
The default setting for the cross sensor timeout is
10 seconds.
•
To change the timeout duration, enter a valued
between 11 to 120 seconds.
Q35: Abort Window Dialer Delay (0-2)
DEFAULT: (1) 30 Seconds
The default minimum setting for ANSI/SIA CP‐01 compliance
is 30 seconds.
The delay time can be increased to 45 seconds without
affecting ANSI/SIA CP‐01 compliance only if the
combination of Q35 and Q6 or Q7 does not exceed one (1)
minute.
NOTE: The dialer delay can be disabled for each sensor
without affecting ANSI/SIA CP‐01 compliance. See "RF
Sensor Programming Questions" on page 42.
The dialer (digital communicator) delays calling the Central
Station to allow the user enough time to cancel a false
alarm before it is reported.
•
The default setting is (1) 30 Seconds.
•
To change the setting, select (0) 15 Seconds or (2)
45 Seconds.
Q36: Burglary Bell Cutoff (0 to 4)
DEFAULT: (0) 4 Minutes
When a burglary alarm is triggered, the bell will sound until
the burglary bell cutoff time expires.
•
The default setting for the burglary bell cutoff is (0)
4 Minutes.
•
To change the cutoff time, select an option below.
Burglary Bell Cutoff Time
(0) 4 Minutes
(1) 8 Minutes
(2) 12 Minutes
(3) 16 Minutes
(4) Unlimited
NOTE: The 24‐hour Auxiliary Alarm Zone (08) does not
follow the burglary bell cutoff time and will sound the
Control Panel's local alarm until a User Code is entered.
The Auxiliary Alarm Zone does not trigger the external
siren (if used).
58
Copyright © 2014 Linear LLC
Q37: Fire Bell Cutoff (0-4)
DEFAULT: (0) 4 Minutes
When a fire alarm is triggered, the bell sounds until the fire
bell cutoff time expires.
•
The default setting (0) 4 Minutes sets the burglary
bell cutoff to four (4) minutes.
•
To change the fire bell cutoff time, select an option
below
Fire Bell Cutoff Time
(0) 4 minutes
(1) 8 minutes
(2) 12 minutes
(3) 16 minutes
(4) Unlimited
Q38: Time to Detect AC Loss, in Minutes
(0-30)
DEFAULT: (10) 10 Minutes
When AC power is lost, they system displays a power loss
alert
after the specified time length. When power is
restored, the alert is automatically cleared after one (1)
minute.
•
The default detection timer for displaying the alert
message is (10) 10 Minutes.
•
To change the detection timer, enter a value
between 0 to 30 minutes.
NOTE: After the AC power alert
the AC power loss report or AC power restore report
can be sent to the Central Station immediately, or at a
random time, see Q39: Random AC Loss Report Time.
NOTE: The Control Panel's AC Power Icon immediately
displays the power status. See "AC Power On/OFF" on
page 29.
is displayed or clears,