Q: Select RF Keypad# Emergency Keys (0 to 1)
DEFAULT: (1) Enabled
NOTE: This step is not displayed for Wireless Touch Screen 
keypads.
Standard wireless keypads have 24‐hour emergency 
buttons labeled Fire and Police.
The default (1) enables this RF Keypad's emergency 
keys.
To disable this RF Keypad's emergency keys, select 
disabled (0), the keys will not be able to trigger an 
alarm or report.
NOTE: The RF Keypad's POLICE button triggers a silent 
alarm if programming question Q16: Police Emergency 
Key (0‐2) is set to (2) Silent Panic.
IMPORTANT: To ensure that a signal is sent, instruct the 
end user to press and hold down the emergency key on 
the keypad until its indicator light illuminates.
Q: Construct RF Keypad# Voice Descriptor
DEFAULT: (#) Keypad
The voice descriptor is the words the Control Panel will 
announce for this RF Keypad. Up to five words are allowed.
Press Insert to place a word from the vocabulary into 
1
the data entry field.
2
Use the ← or → arrows to scroll through the words, or 
enter the word's 3‐digit index number.
Press Insert again for the next word. Up to five words 
3
are allowed.
To remove a word, press Delete.