Q: Select RF Keypad# Emergency Keys (0 to 1)
DEFAULT: (1) Enabled
NOTE: This step is not displayed for Wireless Touch Screen
keypads.
Standard wireless keypads have 24‐hour emergency
buttons labeled Fire and Police.
•
The default (1) enables this RF Keypad's emergency
keys.
•
To disable this RF Keypad's emergency keys, select
disabled (0), the keys will not be able to trigger an
alarm or report.
NOTE: The RF Keypad's POLICE button triggers a silent
alarm if programming question Q16: Police Emergency
Key (0‐2) is set to (2) Silent Panic.
IMPORTANT: To ensure that a signal is sent, instruct the
end user to press and hold down the emergency key on
the keypad until its indicator light illuminates.
Q: Construct RF Keypad# Voice Descriptor
DEFAULT: (#) Keypad
The voice descriptor is the words the Control Panel will
announce for this RF Keypad. Up to five words are allowed.
Press Insert to place a word from the vocabulary into
1
the data entry field.
2
Use the ← or → arrows to scroll through the words, or
enter the word's 3‐digit index number.
Press Insert again for the next word. Up to five words
3
are allowed.
To remove a word, press Delete.
4
Installer Programming
Copyright © 2014 Linear LLC
53
Need help?