INSTALLER PROGRAMMING
ACCOUNT REGISTRATION
The account registration process is used to enroll the
Control Panel with remote service provider's Central
Station.
Typically, the account registration data is created with the
service installation contract and then stored in a database
managed by the Central Station. The data includes items
such as the customer name, address, and the Central
Station telephone number and account number assigned
to the Control Panel.
If you will be installing the 2GIG Go!Bridge IP
Communicator, additional registration information
required. For details, see the Installation Instructions
included with the Go!Bridge IP Communicator.
WIRELESS (RF) SENSOR
PROGRAMMING
The Control Panel can be programmed with up to 48 RF
sensors of different types. In addition to the 48 multi‐
purpose RF sensors, you can also program eight (8) RF
remote control key fobs and four (4) RF remote control
keypads into the system.
RF sensors # 01‐48 report as system sensors 01‐48.
Programming questions for RF sensor programming
include:
•
Q1: Select RF Sensor Number. Select sensor number
01‐48.
•
Q: Select RF Sensor # Type. Select (01) Exit/Entry 1,
(02) Exit/Entry 2, (03) Perimeter, and so on. For
options, see "Sensor Types (Zones)" on page 36.
•
Q: Select RF Sensor # Equipment Type. Some
sensor types ask for the equipment type, others do
not. See "Q: Select RF Sensor # Equipment Type" on
page 43.
•
Q: Select RF Sensor # Equipment Code. Select the
four (4)‐digit equipment code for the sensor
model. See "Equipment Codes" on page 40.
•
Q: Select RF Sensor # Other Equipment Code. If
you select (0000) Other in the previous question,
you must enter this code.
•
Q: Enter RF Sensor # Serial #. Enter the serial
number (typically a label on the sensor or its
packaging) or press Shift then Learn on the panel.
Then trip the sensor to transmit the serial number
to the panel.
•
Q: Select RF Sensor # Equipment Age. Specify
whether the sensor is (0) New or (1) Existing.
•
Q: Select RF Sensor # Loop Number. Specify the
appropriate loop number(s) for the sensor. See "Q:
Select RF Sensor # Loop Number (1 to 3)" on page
44.
•
Q: Select RF Sensor # Dialer Delay. Delayed or
instant digital communicator reports for the sensor.
The delay time is set using the Dialer Abort screen.
•
Q: Construct RF Sensor # Voice Descriptor. Name
assigned to the sensor and announced if
programmed.
•
Q: Select RF Sensor # Reports. Specify (0) Disabled
or (1) Enabled whether RF sensors trigger a report
to the Central Station or not.
•
Q: Select RF Sensor # Supervised. Control Panel
checks for status reports from the sensor, or does
not check for status reports]
•
Q: RF Sensor # Chime. Select voice announcement
and chime options for the sensor.
Q1: RF Sensor Programming Outline
Figure 50 RF Sensor Programming Outline
Copyright © 2014 Linear LLC
41