Q: Select Wired Sensor# Dialer Delay (0 To 1) - 2gig Technologies Go!Control Panel Installation & Programming Manual

Wireless security system
Hide thumbs Also See for Go!Control Panel:
Table of Contents

Advertisement

Q: Select Wired Sensor# Normal State
DEFAULT: (0) Not Used
The two hardwire loops can be wired for normally open (N/
O) or normally closed (N/C) contacts, or for end‐of‐line 
(EOL) resistor.
The default setting (0) Not Used disables this wired 
sensor.
To use this wired sensor, select the way the loop is 
wired:
Wired Sensor Normal State
(0) Not Used
(1) Closed
(2) Open
(3) End‐of‐Line Resistor
Q: Select Wired Sensor# Dialer Delay (0 to 1)
DEFAULT: (1) Enabled
If this feature is enabled, the delay time must be set to a 
minimum of 30 seconds for ANSI/SIA compliance. To set the 
delay time, see "Q35: Abort Window Dialer Delay (0‐2)" on 
page 58.
Wired sensors can trigger the digital communicator 
immediately or after a delay. 
The default setting (1) Enabled causes delayed 
dialing for this wired sensor number.
For immediate dialing for this wired sensor number, 
select (0) Disabled.
Q: Construct Wired Sensor # Voice Descriptor
DEFAULT: No Default
NOTE: For a list of voice descriptors, see "Voice Descriptors" 
on page 38.
The voice descriptors are the words the Control Panel will 
announce for this wired sensor if this wired sensor is 
programmed for voice annunciation. Up to five words are 
allowed.
Press Insert to place a word from the vocabulary into 
1
the data entry field.
Use the ← or → arrows to scroll through the words, or 
2
enter the word's three (3)‐digit number.
Press Insert again for the next word. Up to five words 
3
are allowed.
To move between words, press the Fwd and Back 
4
buttons.
To remove a word, press Delete.
5
Q: Select Wired Sensor# Reports (0 to 1)
DEFAULT: (1) Enabled
Wired sensors can be programmed to trigger a report to the 
Central Station or not.
The default setting (1) Enabled activates reporting for 
this wired sensor number.
To prevent reporting for this wired sensor number, 
select (0) Disabled.
Q: Select Wired Sensor# Chime (00 to 13)
DEFAULT: (0) Disabled
Each wired sensor can be set to sound a "ding‐dong" chime 
and/or sound its
voice descriptor when the sensor is triggered.
The default setting (0) Disabled inactivates the 
chime for this wired sensor.
If a chime and/or voice is required for this wired 
sensor, choose one of the other chime options:
Sensor Chime
Code  Sensor Chime
(0) 
Disabled
(1) 
Voice Only
(2) 
Ding‐Dong with Voice #1
(3) 
Ding‐Dong #2
(4) 
Ding‐Dong with Voice #2
(5) 
Ding‐Dong #1
(6) 
Ding‐Ding
(7)
Ding‐Ding with Voice
(8) 
Ding‐Dong #3
(9) 
Ding‐Dong with Voice #3
(10)  Chime #1
(11)  Chime #1 with Voice #1
(12)  Chime #2
(13)  Chime #2 with Voice #2
Copyright © 2014 Linear LLC
Installer Programming
47