Upgrading The Core Software - Avaya 4600 Series Installation Manual

Hide thumbs Also See for 4600 Series:
Table of Contents

Advertisement

IP Office Installation

1 5. Upgrading the Core Software

6 9 B
The installed IP Office Manager includes .bin core software files appropriate to the software level. It can
be used to load those .bin file into the control unit and module within the IP Office system.
WARNINGS
Check IP Office Technical Bulletins
Check the latest IP Office Technical Bulletin for the IP Office software release before proceeding
any further. It may contain information relating to changes that occurred after this document was
completed. Bulletins are available from http://support.avaya.com.
WAN3 and WAN3 10/100 Modules
Upgrade each WAN3 module separately and only after having upgraded the control unit and any
other expansion modules.
Upgrading pre-Level 2.1 Systems
For IP Office Systems with software Level 2.0 or earlier, the upgrade procedure must be done
from a PC with a fixed IP address on the same subnet and LAN segment as the IP Office.
Multi-Stage Upgrades
Due to the need to adjust internal memory allocation, for certain upgrades some control units
need to perform a multi-stage upgrade process.
Control
Upgrade
Unit
IP403
To between 2.0 and
2.1(27)
To 2.1(28) or higher
IP406 V1
To 3.1 or higher.
IP406 V2
To 3.1 or higher.
To 3.2 or higher.
Multiple Managers
If more than one copy of Manager is running it is possible for the IP Office to request BIN files
from a different Manager from the one that started the upgrade process. Ensure that only one
copy of Manager is running when upgrading an IP Office system.
Information Required
1.
System Password.
For a new or defaulted system this is password.
Tools Required
1.
Manager PC.
The Upgrade Wizard tool is part of the Manager application.
Installation Manual
IP Office 3.2
Stages Required
The IP403 must first be upgraded to level 1.99.
Once upgrade to 1.99, the unit can be upgraded to levels up to
2.1(27).
The IP403 must first be upgraded to level 2.99.
Once upgraded to 2.99, the unit can be upgraded to 2.1(28) or
higher.
The control unit must first be upgraded to level 3.0(999).
Once upgraded to 3.0(999), the unit can be upgraded to 3.1.
The control unit must first be upgraded to level 3.0(999).
Once upgraded to 3.0(999), the unit can be upgraded to 3.1.
The control unit must first be upgraded to level 3.1(999).
Once upgraded to 3.1(999), the unit can be upgraded to 3.2.
15-601042 Issue 14b (13th November 2007)