IP Office Installation
Analog Trunk Module Connections
Ports
Description
ANALOG
RJ45 socket. Used for connection to analog trunks. Ports can be configured as either
loop-start or ground-start trunks through the IP Office configuration.
In the event of power failure, Analog ports 1 and 2 are directly connected to analog
extension ports PF1 and PF2 respectively. If used the connected phones must be
clearly labeled as power failure devices. This is only supported for loop-start analog
trunks.
DC I/P
DC power input port. Used for connection of the power lead from an Avaya 40W
external power supply unit supplied with the expansion module. A locale specific
IEC60320 C7 power cord for the external PSU is required but is not supplied with the
module.
DTE
25-Way D-Type socket. For Avaya use only.
EXPANSION RJ45 Socket. Used for direct connection to an Expansion port on an IP Office control
unit using the Expansion Interconnect cable supplied with the module.
PF
RJ45 socket. Power failure analog extension ports. See Analog section above.
Ground point. Used for connection of a protective or functional ground if required. On
older modules where this screw is not present, the top-center cover screw should be
used instead.
In all IP Office installations, any module being used for analog trunk connections must
be connected to a functional earth.
Within the Republic of South Africa and in areas of high lightning risk, any module using
analog trunk connections must be connected to a protective ground and to surge
protection equipment (an Avaya 146G Surge Protector).
All expansion modules are supplied with a base software level and should be upgraded to match the
core software of the control unit in the IP Office system.
Item
IP400 Analog Trunk 16
IEC60320 C7 Power Cord
Rack Mounting Kit
Expansion modules include an external power supply unit (PSU) and an appropriate interconnect cable.
They do not include a locale specific power cord for the external PSU or any phone extension cables.
Installation Manual
IP Office 3.2
IMPORTANT
WARNING
Variant
Country
America
America
Europe
Europe
New Zealand New Zealand
CEE7/16
Europe
BS1363
United Kingdom 700213374
NEMA1-15
America
Korea
Korea
China
China
All
15-601042 Issue 14b (13th November 2007)
SAP Code
700211360
700241680
700241698
700213382
700213390
700254519
700314172
700210800