Cat Mode Setting Procedure; Notice On The Cat Mode - NEC NEAX 2000 IVS Command Manual

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

INFORMATION FOR DATA PROGRAMMING
2.1.2

CAT Mode Setting Procedure

To set CAT mode:
1. Press
TRF
2. Press
CNF
– CNF lamp flashes
3. Press
*
– CNF lamp off
4. Press
TRF
Note:
To clear CAT mode:
While "COMMAND =– is displayed on the LCD.
1. Lift handset (Off Hook)
- SPKR lamp off.
2. Replace handset (On Hook)
- CNF, ANS lamps off.
- LCD returns to clock.
2.1.3

Notice on the CAT Mode

(1) CAT mode is used in on-line mode. Therefore, system data clear commands (CM00, CM01) cannot be
accessed from the CAT.
(2) To use the CAT after clearing all system data, perform the following operations on the system:
(a) Plug a PN-2DLCB/4DLCA card into the LT00 slot of PIM0.
(b) Connect the CAT (Multiline Terminal) to LEN0000 at the MDF.
(c) Set SW3 on the MP card to "B".
(d) Depress SW1 on the MP card. (System Data All Clear)
(e) Set SW3 on the MP card to "0", and depress SW1. (On-Line mode)
(f) Set the CAT mode on the Multiline Terminal.
(3) During CAT mode, do not change or delete the following data:
CM10, My Line Number of the CAT.
(4) There are no limitations on the number of Multiline Terminals in the system that can be programmed to
allow CAT capability. However, the number of Multiline Terminals that can be placed into CAT mode, at
the same time, is two.
CHAPTER 2
Page 6
Revision 2.0
Steps 1 through 6 need to be completed within 4 seconds.
5. Press
CNF
– CNF lamp flashes
6. Press
#
– CNF, SPKR, ANS lamp on
– "CAT MODE" displayed on LCD
7. Press
ST
– "COMMAND=–" displayed on LCD
ND-45669 (E)