CM61
COMMAND CODE
61
MAT
1.
FUNCTION:
This command is used to activate and specify the function of the switch closure detection circuit
(PN-DK00) card when interfaced with external keys.
2.
PRECAUTION:
This command is included in MAT mode menu "E4" (External Key function [COM02]).
3.
ASSIGNMENT PROCEDURE:
ST
+ 61YY
4.
DATA TABLE:
KEY NUMBER
No.
MEANING
XXX
XX
X
Circuit No.
(0-3)
Card No.
(00-63)
Note: Card number
corresponds
to 00 - 63 of
CM10 E900 -
E963.
CHAPTER 3
Page 234
Revision 2.2
[CM61]
External Key Function
TITLE:
EXTERNAL KEY FUNCTION
KEY NUMBER
+
DE
+
(3 digits)
No.
00
Destination of Tenant
(TN)
01
Change Day/Night trunk re-
(A0)
striction Class by external
key
03
Outgoing call restriction on
(A2)
night mode by external key
05
Day/Night mode change by
(A4)
external key
06
Even if station-to-station
(A5)
call is restricted, calling
tenant is allowed to cancel
restriction by external key
30
External key for alarm
clearing
Addendum-002
JANUARY, 1999
DATA
+
DE
+
(1 - 3 digits)
YY
MEANING
DATA
00
63
0
1
0
1
0
1
0
1
00
ND-45669 (E)
+ EXE
SETTING DATA
COMMAND
MEANING
Tenant 00
Tenant 63
Effective
CM12
Ineffective
YY = 01
Effective
CM30
Ineffective
YY = 08
Effective
CM30 YY = 02,
Ineffective
03, 04, 05, 13,
14, 26
CM76 Y = 0, 1
CM58
YY = 02 - 09
Effective
CM63
Ineffective
Y = 1
MJ/MN Alarm
Clear key
Initial Data
: