COMMAND CODE
45
Y
No.
MEANING
9
Receiving dB level of
PBR
TITLE:
PURPOSE OF PBR/CFT
PBR/CFT NUMBER
No.
MEANING
XXX
XX X
Circuit
Number (0-3)
Card Number
(00-15)
ND-45669 (E)
Addendum-002
JANUARY, 1999
SETTING DATA
DATA
MEANING
00
–22.6 dBm
01
–23.3
02
–24.0
03
–24.8
04
–25.8
05
–27.0
06
–27.7
07
–28.3
08
–29.1
09
–29.8
10
–30.6
11
–31.4
12
–32.3
13
–33.7
14
–34.5
15
–26.4
16
–36.4
17
–37.0
18
–37.8
19
–38.6
20
–39.3
21
–41.0
22
–42.0
23
–43.1
24
–44.2
25
–45.5
26
–46.5
27
–47.8
28
–49.1
29
–50.2
30
–51.5
31
–40.1
CM45
Initial Data
: