NEC NEAX 2000 IVS Command Manual page 231

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

CM42
COMMAND CODE
42
4.
DATA TABLE:
4.1
System Counter Data
Note: Initial data in the Data Table represents the value for the data "NONE".
KIND OF SYSTEM COUNTER
00
Number of waiting calls which
will cause attendant's Call Wait-
ing LCD to flash.
01
Number of stations in Line Lock-
out to give MN (minor) alarm.
03
Number of Wake-Up/Timed Re-
minder call attempts before aban-
donment.
04
Maximum number of stations that
are able to set Wake-Up/Timed
Reminder call for the same Wake-
Up Time
08
Maximum number of trunks to be
seized serially when a designated
trunk is busy (for Private Lines)
10
Maximum number of digits for
Account Code
11
Maximum number of digits for
Authorization Code
12
Maximum number of digits for
Forced Account Code
13
Maximum number of digits for ID
code on Direct Inward System Ac-
cess (DISA)
CHAPTER 3
Page 198
Revision 2.0
TITLE:
SYSTEM COUNTER DATA/PAD DATA/TRUNK RESTRICTION CLASS
CONVERSION
INITIAL
DATA
06
None
Note 1
05
16
00
10
10
(8)
Note 2
10
(8)
Note 2
10
(10)
Note 2
ND-45669 (E)
SETTING DATA
01
Number of Waiting Calls
48
01
Number of Lockout Sta-
tions
99
01
Number of attempted
Wake-Up/Timed Re-
15
minder calls
01
Max. number of stations
32
01
Number of trunks
16
01
Max. number of digits
16
01
Max. number of digits
10
1
Max. number of digits
10
01
Max. number of digits
10
REMARKS
Related Commands:
CM12 YY = 16
CM35 YY = 98
When CM08-216=0,
Max. 8 digits are
available and initial
data is 8.
When CM08-216 = 0,
Max. 8 digits are
available and initial
data is 8.
Note 3
When CM08-217 = 0,
Max. 16 digits are
available.

Advertisement

Table of Contents
loading