1. GENERAL

The resident system program generates system data automatically according to the system hardware configu-
ration, thereby providing immediate operation and shorter programming time. When activated, the system
scans hardware configuration (such as line/trunk card location) and assigns the system data (such as station
numbers, trunk numbers, etc.) according to a predetermined generic program assignment.

2. PROCEDURE FOR LOADING THE RESIDENT SYSTEM PROGRAM

STEP 1
Mount the cards on PIMs.
STEP 2
Set SW3 of the MP card to "C".
STEP 3
Press SW1 of the MP card.
STEP 4
Confirm the status of MJ/MN lamp on the PWR card.
When the MN lamp lights, the office data is normally registered.
When the MJ lamp lights, the office data is not normally registered.
Repeat STEP 2 and STEP 3.
STEP 5
Set SW3 of the MP card to "0".
STEP 6
Press SW1 of the MP card.

3. SERVICE CONDITIONS

(1) This service is applicable for equipment installed in PIM 0 through PIM 3.
(2) Data for any vacant slot is not assigned.
(3) Virtual stations are not assigned.
(4) A line/trunk card (PN-AUCA/DK00/CFT) is not assigned, even if mounted.
(5) An application card (PN-AP00/AP01/24DTA/SC00/SC01/ME00) is not assigned, even if mounted.
(6) No tenant assignment is provided.
(Tenant 01 is assigned)
(7) Details of Resident System Program
For the other commands which are not described in Table 4-1 through Table 4-11, the initial data is loaded