INFORMATION FOR DATA PROGRAMMING
(1) Example: When Station Number 300 is to be assigned to LEN 0000 and Station Number 301 to LEN 0001
by CM10 (Refer to
STEP 1
Turn ON power switch.
STEP 2
Press
STEP 3
Enter "10" (Command Number).
STEP 4
Press
STEP 5
Enter "0000" (LEN).
STEP 6
Press
STEP 7
Enter "300" (Station Number).
STEP 8
Press
STEP 9
Press
STEP 10
Press
STEP 11
Enter "301" (Station Number).
STEP 12
Press
STEP 13
Press
STEP 14
Turn OFF power switch.
Note 1:
When no data exists, "NONE" is displayed. And when data exists, that data is displayed.
This
Note 2:
DE
CHAPTER 2
Page 8
Revision 2.0
Table
2-3.)

Table 2-3 Assignment Operation

.
ST
.
DE
.
DE
.
EXE
.
DE
.
S
.
EXE
.
DE
operation is for confirming the data assignment. Thus it may be omitted.
(DISPLAY)
_
COMMAND = _
COMMAND = 10 _
10> _
10> 0000_
10> 0000: NONE-_
10> 0000: NONE-300
OK _
10> 0000: 300-_
10> 0001: NONE__
10> 0001: NONE-301
OK _
10> 001 : 301 _
ND-45669 (E)
Note 1
Note 2
Note 1
Note 2