CMF5
COMMAND CODE
F5
(6) Line/Trunk Memory/Alarm Memory Read (CMF5)
The following shows the steps for performing a memory read using the MAT/CAT.
ST
+
F5Y
Y
0
X
Single Line Station/Virtual Line Station
Number (1-4 digits) X=0-9, A(*), B(#)
XXXX
FX
Multiline Terminal Number <X-XXXX>
represents Primary Extension Number
FXXXX
D000
Trunk Number
D255
2
X
Single Line Station/Virtual Line Station
Number (1-4 digits) X-0-9, A(*), B(#)
XXXX
X
Multiline Terminal Number <X-XXXX>
represents Primary Extension Number
FXXX
D000
Trunk Number
D255
3
000
Memory Dump Data
003
004
CHAPTER 3
Page 366
Revision 2.0
[CMF5]
Special Commands
TITLE:
SPECIAL COMMANDS
1ST DATA
+
DE
+
1ST DATA
+
DE
READOUT DATA
(STATUS INFORMATION)
Status of Station/Trunk
LEN Number
Reason for initialization
MP initialization time
FP initialization time
ND-45669 (E)