[Cma6] Attribute Data For Rs-232C Port On Ap01 - NEC NEAX 2000 IVS Command Manual

Hide thumbs Also See for NEAX 2000 IVS:
Table of Contents

Advertisement

COMMAND CODE
A6
MAT
1.
FUNCTION:
This command is used to assign the attribute data for the RS-232C port on the PN-AP01 card.
2.
PRECAUTION:
None
3.
ASSIGNMENT PROCEDURE:
ST + A6YY + DE + 3 +
4.
DATA TABLE:
YY
No.
MEANING
04
Data Transmission Speed of
RS-232C Port
05
Parity Check
06
Synchronous/Asynchronous
07
Duplex or half-duplex
[CMA6]
Attribute Data For RS-232C Port On AP01
TITLE:
ATTRIBUTE DATA FOR RS-232C PORT ON AP01
DATA
(1 - 2 digits) + EXE
DATA
0
1
2
3
4
5
6
0
1
0
3
7
0
1
ND-45669 (E)
SETTING DATA
MEANING
150 bps
300 bps
600 bps
1200 bps
2400 bps
4800 bps
9600 bps
Effective
Ineffective
Synchronous Transmission by
Internal
Synchronous Transmission by
External
Asynchronous
Half-duplex
Duplex
CMA6
Initial Data
:
RECOMMENDED
SETTING
5
(example)
1
7
1
CHAPTER 3
Page 317
Revision 2.0

Advertisement

Table of Contents
loading

Table of Contents