COMMAND CODE
90
MAT
YY
No.
MEANING
00
Setting of Functions
(Key
Data)
01
Tone Ringer enabled on
(RG)
call termination
03
Ringing sending method
(RG)
when terminating a call
to Line/Trunk key on the
Multiline Terminal
05
Call Indicator Lamp
Control
TITLE:
MULTILINE TERMINAL/SN610 ATTCON/ADD-ON MODULE KEY ASSIGNMENT
DATA
F6010
Call Termination from FX Line 0 (FX0)
F6017
Call Termination from FX Line 7 (FX7)
F6020
Call Termination from WATS Line 0
(WATS0)
F6027
Call Termination from WATS Line 7
(WATS7)
F6030
Call Termination from CCSA Line 0
(CCSA0)
F6037
Call Termination from CCSA Line 7
(CCSA7)
F7XXX
0
Disabled
1
Enabled
0
Delayed ringing
1
No delayed ringing
0
Not available
1
Available
(The lamp lights on call termination or
recall)
ND-45669 (E)
SETTING DATA
MEANING
XX
X
Circuit No. (0-3)
assigned by CM44
Card No. (00-31)
assigned by CM44
CM90
Initial Data
:
RELATED
COMMAND
CM35 YY=15
CM35 YY=15
CM35 YY=15
CM44-XXX-1500
CM41 Y=1
Function No. 09
CHAPTER 3
Page 291
Revision 2.0