Configuration 111 - Sensorless Control With Technology Controller; Configuration 410 - Sensorless Field-Oriented Control - BONFIGLIOLI Act 201 Operating Instructions Manual

Vectron active 201/401 series 230v/400v 0.55 kw ... 132. kw frequency inverter
Hide thumbs Also See for Act 201:
Table of Contents

Advertisement

5.6.2.2
Configuration 111 extends the functionality of the sensorless control by software func-
tions for easier adaptation to the customer's requirements in different applications.
The Technology Controller enables flow rate, pressure, level or speed control.
5.6.2.3
Configuration 410 contains the functions for sensorless, field-oriented control of a 3-
phase machine. The current motor speed is determined from the present currents and
voltages in combination with the machine parameters. Separate control of torque and
flux-forming current enables a high drive dynamics at a high load moment.
52
52
Configuration 111 – Sensorless Control with Technol-
ogy Controller
X210A
1
+20 V/180 mA
GND 20 V
2
3
S1IND
S2IND
4
5
S3IND
6
S4IND
7
S5IND
M
X210B
1
S6IND
GND 20 V
2
-
+
S1OUT
3
-
+
MFO1A
V
4
5
+10 V/4 mA
+
MFI1A
6
GND 10 V
7
-
Configuration 410 – Sensorless Field-Oriented Con-
trol
X210A
1
+20 V/180 mA
2
GND 20 V
3
S1IND
S2IND
4
5
S3IND
6
S4IND
7
S5IND
M
X210B
1
S6IND
GND 20 V
2
-
+
S1OUT
3
-
+
MFO1A
V
4
+10 V/4 mA
5
MFI1A
6
GND 10 V
7
Operating Instructions ACTIVE
Operating Instructions ACTIVE
Control terminal X210A
X210A.1
Supply voltage +20 V
X210A.2
Ground 20 V
X210A.3
Controller release / error acknowl-
edgment
X210A.4
Fixed percentage value change-
over 1
X210A.5
Fixed percentage value change-
over 2
X210A.6
Data set change-over 1
X210A.7
Data set change-over 2
Control terminal X210B
X210B.1
Motor thermal contact
X210B.2
Ground 20 V
X210B.3
Operating message
X210B.4
Analog signal of actual frequency
X210B.5
Supply voltage +10 V
X210B.6
Actual percentage value 0 ...+10 V
X210B.7
Ground 10 V
Control terminal X210A
X210A.1
Supply voltage +20 V
X210A.2
Ground 20 V
X210A.3
Controller release / error acknowl-
edgment
X210A.4
Start of clockwise operation
X210A.5
Start of anticlockwise operation
X210A.6
Data set change-over 1
X210A.7
Data set change-over 2
Control terminal X210B
X210B.1
Motor thermal contact
X210B.2
Ground 20 V
X210B.3
Operating message
X210B.4
Analog signal of actual frequency
X210B.5
Supply voltage +10 V
Reference value potentiometer
X210B.6
Reference speed 0 ...+10 V
X210B.7
Ground 10 V
06/07
06/07

Hide quick links:

Advertisement

Table of Contents
loading