The error and warning messages can be read out by means of the digital outputs or
reported to an overriding control system. The
rameterized as a percentage of the
possible operating points.
No.
582 Trigger Limit Iactive
583 Delay Time
17.7
The field-orientated control modes are based on a cascade control and the calculation
of a complex machine model. The various control functions can be supplemented by
special functions specific to the application.

17.7.1 Motor Chopper

The field-orientated control modes contain the function for adapted implementation of
the generator energy into heat in the connected three-phase machine. This enables
the realization of dynamic speed changes at minimum system costs. The torque and
speed behavior of the drive system is not influenced by the parameterized braking
behavior. The parameter
switch-on threshold of the motor chopper function.
No.
507 Trigger Threshold
The parameter
the maximum DC link voltage which the mains can generate and the maximum admis-
sible DC link voltage of the frequency inverter.
If the parameter
DC link voltage, the motor chopper cannot become active, the motor chopper is
switched off.
If the set
mains can generate, error message F0706 (chapter "Error Messages") is displayed
when the frequency inverter is switched on.
06/07
06/07
Parameter
Description
Functions of Field-Orientated Control
Trigger Threshold
Parameter
Description
Trigger Threshold
U
Mains
Trigger Threshold
Trigger Threshold
507 is smaller than the maximum DC link voltage the
Operating Instructions ACTIVE
Operating Instructions ACTIVE
Trigger Limit Iactive
Rated Current
371 for the application and the
Min.
0.1%
0.1 s
507 of the DC link voltage defines the
Min.
U
+25V
dmin
507 is to be set in such a way that it is between
1.1
2
<
U
<
Ud
dMC
507 is set larger than the maximum admissible
582 is to be pa-
Settings
Max.
Fact. sett.
100.0 %
10.0 %
600.0 s
10.0 s
Settings
Max.
Fact. sett.
1000.0
U
dMC
max
189
189