Comply with the notes for controlling a mechanical brake in chapter 14.3.4 Open
brake.
06/07
06/07
Stopping behavior 0
Free stopping
Stopping behavior 1
Stop
+ Switch off
Stopping behavior 2
Stop + Hold
Stopping behavior 3
Stop + DC brakes
Stopping behavior 4
Emergency stop
+ switch off
Stopping behavior 5
Emergency stop +
Hold
Stopping behavior 6
Emergency stop +
Brake
Stopping behavior 7
Direct current brake
Operating Instructions ACTIVE
Operating Instructions ACTIVE
Stopping Behavior
The inverter is disabled immediately. The drive deener-
gized immediately and coasts freely.
The drive is brought to a standstill at the set deceleration.
As soon as the drive is at a standstill, the inverter is dis-
abled after a holding time. The holding time can be set via
Holding Time
the parameter
Depending on the setting of the parameter
tion
Starting Current
620, the
Starting Voltage
600 is applied for the duration of the
holding time.
The drive is brought to a standstill at the set deceleration
and remains permanently supplied with current.
Depending on the setting of the parameter
tion
Starting Current
620, the
Starting Voltage
standstill or the
The drive is brought to a standstill at the set deceleration.
As from standstill, the direct current set via parameter
Braking Current
631 is impressed for the
632.
Comply with the notes in chapter "DC brake".
Stopping behaviors 3, 6 and 7 are only available in the
configurations for sensor-less control.
The drive is brought to a standstill at the emergency stop
deceleration. As soon as the drive is at a standstill, the
inverter is disabled after a holding time.
The holding time can be set via the parameter
Time
638. Depending on the setting of the parameter
Starting Function
620, the
pressed as from standstill or the
applied.
The drive is brought to a standstill at the set emergency
stop deceleration and remains permanently supplied with
current.
Depending on the setting of the parameter
tion
Starting Current
620, the
Starting Voltage
standstill or the
The drive is brought to a standstill at the set emergency
stop deceleration. As from standstill, the direct current set
Braking Current
via parameter
Braking Time
632.
Comply with the notes in chapter "DC brake".
Stopping behaviors 3, 6 and 7 are only available in the
configurations for sensor-less control.
Direct current braking is activated immediately. The direct
current set with the parameter
Braking Time
impressed for the die
Comply with the notes in chapter "DC brake".
Stopping behaviors 3, 6 and 7 are only available in the
configurations for sensor-less control.
638.
Starting Func-
623 is impressed or the
Starting func-
623 is impressed as from
600 is applied.
Braking Time
Holding
Starting Current
623 is im-
Starting Voltage
600 is
Starting Func-
623 is impressed as from
600 is applied.
631 is impressed for the
Braking Current
631 is
632.