3.4

ACT 201 (4.0 up to 9.2 kW, 230 V)

Type
ACT 201
Output motor side
Recommended shaft output
Output current
Long-term overload current (60 s)
Short-term overload current (1 s)
Output voltage
Protection
Rotary field frequency
Switching frequency
Output brake resistor
min. brake resistor
Recommended brake resistor
(U
= 385 V)
dBC
Input, mains side
Mains current
3)
, 3ph/PE
1ph/N/PE; 2ph/PE
Mains voltage
Mains frequency
Fuse 3ph/PE
1ph/N/PE; 2ph/PE
UL Type 250 VAC RK5, 3ph/PE
1ph/N/PE; 2ph/PE
Mechanics
Dimensions
Weight (approx.)
Degree of protection
Terminals
Form of assembly
Ambient conditions
Energy dissipation
(2 kHz switching frequency)
Coolant temperature
Storage temperature
Transport temperature
Rel. air humidity
If required by the customer, the switching frequency may be increased if the output current is reduced at the
same time. Comply with the applicable standards and regulations for this operating point.
6)
Output current
Frequency inverter nominal power
4.0 kW
4)
5.5 kW
4)
7.5 kW
4)
9.2 kW
Three-phase connection requires a commutating choke.
1)
One- and two-phase connection requires a commutating choke.
2)
Mains current with relative mains impedance ≥ 1% (see chapter„Electrical installation")
3)
three-phase connection
4)
Only
Switching frequency is reduced in thermal limit range.
5)
Maximum current in continuous operation
6)
The device for one-phase connection is not included in the product catalogue. It is available on demand.
7)
06/07
06/07
-18
P
kW
4.0
I
A
18.0
I
A
26.3
I
A
33.0
U
V
Maximum up to mains voltage, three-phase
-
-
f
Hz
0 ... 1000, depending on switching frequency
f
kHz
R
24
R
30
18
I
A
2) 7)
28
U
V
f
Hz
25
I
A
35
20
I
A
mm
250x100x200
HxWxD
m
kg
-
-
2
A
mm
-
-
P
W
200
T
°C
n
T
°C
L
T
°C
T
-
%
2 kHz
4 kHz
2)
2)
18.0 A
18.0 A
1)
1). 5)
23.0 A
22.7 A
1)
1)
32.0 A
32.0 A
1)
1), 5)
40.0 A
38.3 A
Operating Instructions ACTIVE
Operating Instructions ACTIVE
-19
-21
5.5
7.5
22.0
32.0
30.3
44.5
33.0
64.0
Short circuit / earth fault proof
2, 4, 8, 12, 16
24
12
24
16
1)
20
28.2
4)
-
-
184 ... 264
45 ... 66
25
35
4)
-
-
25
30
3.0
IP20 (EN60529)
0.2 ... 6
vertical
225
310
0 ... 40 (3K3 DIN IEC 721-3-3)
-25 ... 55
-25 ... 70
15 ... 85; not condensing
Switching frequency
8 kHz
12 kHz
2)
18.0 A
15.1 A
1), 5)
22.0 A
18.5 A
1)
32.0 A
26.9 A
1), 5)
35.0 A
29.4 A
-22
4)
9.2
35.0
51.5
64.0
12
12
1)
1)
35.6
4)
4)
-
50
4)
4)
-
40
250x125x200
3.7
0.2 ... 16
420
16 kHz
2)
12.2 A
5)
5)
15.0 A
1)
21.8 A
1), 5)
5)
23.8 A
19
19