Set-Up Via The Communication Interface - BONFIGLIOLI Act 201 Operating Instructions Manual

Vectron active 201/401 series 230v/400v 0.55 kw ... 132. kw frequency inverter
Hide thumbs Also See for Act 201:
Table of Contents

Advertisement

7.5
Parameter-setting and commissioning of the frequency inverter via one of the optional
communication interfaces include the plausibility check and the parameter identifica-
tion functions. The parameters can be adjusted by qualified users. The parameter
selection during the guided commissioning procedure includes the basic parameters.
These are based on standard applications of the corresponding configuration and are
therefore useful for commissioning.
Caution!
The parameter
after the selection (if controller release signal is present at digital input S1IND). The
operation modes include functions which are also carried out automatically one after
the other during the guided commissioning procedure.
SETUP Selection
0 - Clear Status
1 - Continue
2 - Abort
10 -
11 -
12 -
13 -
14 -
20 -
21 -
22 -
23 -
24 -
30 -
31 -
32 -
33 -
34 -
82
82

Set-up via the Communication Interface

Parameter settings may only be changed by qualified staff. Before starting
the commissioning process, read the documentation carefully and comply
with the safety instructions.
SETUP Selection
796
The auto set-up routine does not perform a function
The warning message is acknowledged and the auto set-up
routine is continued.
The auto set-up routine is stopped and a RESET of the fre-
quency inverter is performed.
The auto set-up routine is performed in data set 0 and the
Complete Setup,
parameter values are stored in all of the four data sets iden-
DS0
tically.
Complete Setup,
The parameter values of the auto set-up are stored in data
DS1
set 1.
Complete Setup,
The parameter values of the auto set-up are stored in data
DS2
set 2.
Complete Setup,
The parameter values of the auto set-up are stored in data
DS3
set 3.
Complete Setup,
The parameter values of the auto set-up are stored in data
DS4
set 4.
Check Machine
The auto set-up routine checks the rated motor parameters
Data, DS0
in the four data sets.
Check Machine
The rated motor parameters in data set 1 are checked for
Data, DS1
plausibility.
Check Machine
The rated motor parameters in data set 2 are checked for
Data, DS2
plausibility.
Check Machine
The rated motor parameters in data set 3 are checked for
Data, DS3
plausibility.
Check Machine
The rated motor parameters in data set 4 are checked for
Data, DS4
plausibility.
The auto set-up routine determines extended motor data via
Calculation and
the parameter identification feature, calculates dependent
Para-Ident., DS0
parameters and stores the parameter values in all of the four
data sets identically.
Calculation and
Further motor data are measured, dependent parameters are
Para-Ident., DS1
calculated and the parameter values are saved in data set 1.
Calculation and
Further motor data are measured, dependent parameters are
Para-Ident., DS2
calculated and the parameter values are saved in data set 2.
Calculation and
Further motor data are measured, dependent parameters are
Para-Ident., DS3
calculated and the parameter values are saved in data set 3.
Calculation and
Further motor data are measured, dependent parameters are
Para-Ident., DS4
calculated and the parameter values are saved in data set 4.
Operating Instructions ACTIVE
Operating Instructions ACTIVE
796 defines the function which is carried out directly
Function