Protocol Configuration Examples

Protocol Configuration Examples

Point-to-Point (Main Port)
<K100,8,0,1,1>
<K140,0>
<K102,0>
Polling Mode (Main Port)
<K100,4,0,1,1>
<K140,5,23>
<K102,0>
<K143,30>
"User-Defined" Polling Mode (Main Port)
<K100,4,0,1,1>
<K140,5,12>
<K148,,08,09,18,0B,0C,0D>
<K102,0>
<K143,40>
ACK / NAK (Main Port)
<K100,9,0,1,1>
<K140,4>
<K147,,,01,1B,2E,1F>
<K102,1>
<K143,50>
Auxiliary Port
Listed below are several examples of Auxiliary Port commands.
<K101,2,4,0,1,1>
<K101,1,5,0,1,1>
<K101,3,7,0,1,1>
<K101,5,6,0,1,1>
3-22
Baud Rate: 115.2K; Parity: None; Stop Bits: 2; Data Bits: 8
Point-to-Point
RS-232 enabled;
<K102,1>
Baud Rate: 9600; Parity: None; Stop Bits: 2; Data Bits: 8
Polling Mode; Address: 23
RS-232 Point-to-Point polling
30 mS Response Timeout
Baud Rate: 9600; Parity: None; Stop Bits: 2; Data Bits: 8
Polling Mode; Address: 12
Default RES (0x04), REQ=0x08; EOT=0x09; STX=0x18;
ETX=0x0B; ACK=0x0C; NAK=0x0D
RS-232 Point-to-Point polling
40 mS Response Timeout
Baud Rate: 230K; Parity: None; Stop Bits: 2; Data Bits: 8
ACK/NAK
Default RES and REQ (00, disabled); STX=0x01; ETX=0x1B;
ACK=0x2E; NAK=0x1F
RS-422 enabled;
50 mS Response Timeout
Half Duplex; Baud Rate: 9600; Parity: None; Stop Bits: 2; Data Bits: 8
Transparent; Baud Rate: 19.2K; Parity: None; Stop Bits: 2; Data Bits: 8
Full Duplex; Baud Rate: 57.6K; Parity: None; Stop Bits: 2; Data Bits: 8
Command Processing; Baud Rate: 230K; Parity: None; Stop Bits: 2;
Data Bits: 8
= RS-422 enabled
<K102,0>
= RS-232 enabled
MS-4 Imager User's Manual